Displaying report 1-1 of 1.
Reports until 11:33, Monday 07 November 2016
H1 ISC
stefan.ballmer@LIGO.ORG - posted 11:33, Monday 07 November 2016 (31286)
POP_A_RF25 phase and SRCL sensing matrix updated

Doing a PRCL noise injection (into PR2) I noticed that H1:LSC-POP_A_RF45_PHASE_R was ~10deg off. Since changing this phase also affects the SRCL sensing matrix, I updated that one too

Old values:

H1:LSC-POP_A_RF45_PHASE_R 77.3
POP_A_RF9_I to SRCL input matrix (H1:LSC-PD_DOF_MTRX_5_1):  -0.025
POP_A_RF45_I to SRCL input matrix (H1:LSC-PD_DOF_MTRX_5_3):  0.08

New values:

H1:LSC-POP_A_RF45_PHASE_R 86.5
POP_A_RF9_I to SRCL input matrix (H1:LSC-PD_DOF_MTRX_5_1):  -0.0242
POP_A_RF45_I to SRCL input matrix (H1:LSC-PD_DOF_MTRX_5_3):  0.08 (unchanged)