J. Kissel The duty-cycle has been delightfully high, so we've been able to get the two hours needed for 1001.3 Hz data point of the roaming high-frequency calibration line quickly despite this mornings issues (see LHO aLOG 31288). Thus, I'm changing it to the much more time intensive 4 kHz line. Here's the latest status: Frequency Planned Amplitude Planned Duration Actual Amplitude Start Time Stop Time Achieved Duration (Hz) (ct) (hh:mm) (ct) (UTC) (UTC) (hh:mm) --------------------------------------------------------------------------------------------------------------------------------------------------------- 1001.3 35k 02:00 39322.0 Nov 11 2016 21:37:50 UTC Nov 12 2016 03:28:21 UTC ~several hours @ 25 W 1501.3 35k 02:00 39322.0 Oct 24 2016 15:26:57 UTC Oct 31 2016 15:44:29 UTC ~week @ 25 W 2001.3 35k 02:00 39322.0 Oct 17 2016 21:22:03 UTC Oct 24 2016 15:26:57 UTC several days (at both 50W and 25 W) 2501.3 35k 05:00 39322.0 Oct 12 2016 03:20:41 UTC Oct 17 2016 21:22:03 UTC days @ 50 W 3001.3 35k 05:00 39322.0 Oct 06 2016 18:39:26 UTC Oct 12 2016 03:20:41 UTC days @ 50 W 3501.3 35k 05:00 39322.0 Jul 06 2016 18:56:13 UTC Oct 06 2016 18:39:26 UTC months @ 50 W 4001.3 40k 10:00 39322.0 Nov 12 2016 03:28:21 UTC 4301.3 40k 10:00 4501.3 40k 10:00 4801.3 40k 10:00 5001.3 40k 10:00