gabriele.vajente@LIGO.ORG - posted 13:08, Thursday 10 November 2016 - last comment - 14:06, Thursday 10 November 2016(31394)
BruCo scan

Here's the report of a BruCo scan for last night's lock

https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_lho_1162821617/

Some interesting results:

A question for commissioners, should I exclude channels like SUS-ETMY_L2_FASTIMON_* ??

 

_FASTIMON
Images attached to this report
Comments related to this report
brian.lantz@LIGO.ORG - 14:06, Thursday 10 November 2016 (31395)SEI
Correlation between HPI-HAM1 and the REFL mirror RM2 has been seen before - See series of logs on Oct 24.
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=30790
Note that HPI-HAM1 is different than all the other HPI-HAMs (2-6) because HAM1 is the only chamber without an ISI. 