SEI seismometer mass position check - Monthly

T240:

Averaging Mass Centering channels for 10 [sec] ...
2016-11-11 12:46:08.555164

There are 4 T240 proof masses out of range ( > 0.3 [V] )!
ETMY T240 3 DOF Z/W = 0.328 [V]
ITMX T240 1 DOF X/U = -0.47 [V]
ITMX T240 3 DOF X/U = -0.46 [V]
ITMY T240 3 DOF Z/W = -0.743 [V]

All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.093 [V]
ETMX T240 1 DOF Y/V = 0.075 [V]
ETMX T240 1 DOF Z/W = 0.105 [V]
ETMX T240 2 DOF X/U = 0.088 [V]
ETMX T240 2 DOF Y/V = 0.054 [V]
ETMX T240 2 DOF Z/W = 0.111 [V]
ETMX T240 3 DOF X/U = 0.051 [V]
ETMX T240 3 DOF Y/V = 0.022 [V]
ETMX T240 3 DOF Z/W = 0.061 [V]
ETMY T240 1 DOF X/U = -0.03 [V]
ETMY T240 1 DOF Y/V = -0.014 [V]
ETMY T240 1 DOF Z/W = -0.2 [V]
ETMY T240 2 DOF X/U = 0.204 [V]
ETMY T240 2 DOF Y/V = -0.201 [V]
ETMY T240 2 DOF Z/W = 0.011 [V]
ETMY T240 3 DOF X/U = -0.221 [V]
ETMY T240 3 DOF Y/V = -0.04 [V]
ITMX T240 1 DOF Y/V = 0.237 [V]
ITMX T240 1 DOF Z/W = 0.179 [V]
ITMX T240 2 DOF X/U = 0.245 [V]
ITMX T240 2 DOF Y/V = 0.204 [V]
ITMX T240 2 DOF Z/W = 0.232 [V]
ITMX T240 3 DOF Y/V = 0.177 [V]
ITMX T240 3 DOF Z/W = 0.212 [V]
ITMY T240 1 DOF X/U = 0.135 [V]
ITMY T240 1 DOF Y/V = 0.036 [V]
ITMY T240 1 DOF Z/W = 0.036 [V]
ITMY T240 2 DOF X/U = 0.071 [V]
ITMY T240 2 DOF Y/V = 0.172 [V]
ITMY T240 2 DOF Z/W = 0.163 [V]
ITMY T240 3 DOF X/U = -0.195 [V]
ITMY T240 3 DOF Y/V = 0.171 [V]
BS T240 1 DOF X/U = 0.028 [V]
BS T240 1 DOF Y/V = 0.053 [V]
BS T240 1 DOF Z/W = 0.202 [V]
BS T240 2 DOF X/U = 0.135 [V]
BS T240 2 DOF Y/V = 0.184 [V]
BS T240 2 DOF Z/W = 0.174 [V]
BS T240 3 DOF X/U = 0.031 [V]
BS T240 3 DOF Y/V = 0.082 [V]
BS T240 3 DOF Z/W = -0.014 [V]

Assessment complete.

---------

STS:

Averaging Mass Centering channels for 10 [sec] ...

2016-11-11 12:47:53.351902
All STSs prrof masses that within healthy range (< 2.0 [V]). Great!

Here's a list of how they're doing just in case you care:
STS A DOF X/U = -0.537 [V]
STS A DOF Y/V = -0.053 [V]
STS A DOF Z/W = -0.503 [V]
STS B DOF X/U = 0.098 [V]
STS B DOF Y/V = -1.23 [V]
STS B DOF Z/W = -0.064 [V]
STS C DOF X/U = -0.0 [V]
STS C DOF Y/V = -0.0 [V]
STS C DOF Z/W = -0.0 [V]
STS EX DOF X/U = -0.21 [V]
STS EX DOF Y/V = 0.553 [V]
STS EX DOF Z/W = 0.086 [V]
STS EY DOF X/U = 0.027 [V]
STS EY DOF Y/V = 0.315 [V]
STS EY DOF Z/W = 0.298 [V]

Assessment complete.