Displaying report 1-1 of 1.
Reports until 11:09, Friday 15 June 2012
H2 CDS
james.batch@LIGO.ORG - posted 11:09, Friday 15 June 2012 (3144)
Restart of models at Y end
An IRIG-B timing error occurred at about 22:15 UTC June 14, 2012 on all of the front end computers at the Y end station.  This went unnoticed until this morning.  I have corrected the problem by restarting the models on the following computers:

h2pemey
h2susauxb6
h2tcsey
h2pemeyaux

Note that the remaining two computers, h2susb6 and h2seib6 were restarted late yesterday afternoon to correct what appeared to be a RFM error, so the IRIG-B time was reset then.

Models affected:

h2pemey
h2iscey
h2susauxb6
h2tcsetmy
h2pemeyaux
and the IOP models for the computers.

Work completed at 17:45 UTC June 15.
Displaying report 1-1 of 1.