J. Kissel
Travis was able to grab a PCAL2DARM/DARMOLGTF sensing function transfer function set last night (see LHO aLOG 31485) -- for convenience I reiterate the location here:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/Measurements/
PCAL/2016-11-15_H1_PCAL2DARMTF_4to1200Hz_fasttemplate.xml
DARMOLGTFs/2016-11-15_H1_DARM_OLGTF_4to1200Hz_fasttemplate.xml
and attach a screen shot. The data has been committed to the CalSVN.
It looks like the DARM cavity pole was low during this lock stretch, but otherwise the optical gain is ~5% low as we've seen in the last of measurement at 30 [W].
We'll get one more of these at 30 [w] for processing and get on with the analysis. Apologies for the delay in analyzing this data -- I'm really struggling for person power beyond me, given the current poor duty cycle and my needs to be the recovery team as well (Kiwamu's in Canada, Evan's helping out LLO).