Reports until 16:32, Tuesday 15 November 2016
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 16:32, Tuesday 15 November 2016 (31517)
CDS maintenance summary, Tuesday 15th November 2016

WP6314 h1oaf0 stability

Richard, Fil, Daniel, Jim, Dave:

h1oaf0 has been stable since 12:46 Mon 14th PST, no further work was done on this system

WP6312 adding new MD5 DAQ epics channels to the DAQ

Dave:

A new H1EDCU_DAQ.ini file was generated and installed during a DAQ restart at 12:11PST.

WP6315 updated frame-cpp on frame writers

Jim, Jonathan, Dave

The new code (which has been running on h1fw2 for the past week) was installed on h1fw0. Jonathan has test code to look at frames written by fw0 (new) and fw1 (old) to check they are identical. We will test for several days before the decision to upgrade fw1 is made.

WP6318 bug fix in h1susauxb123 model

Jeff:

New code for h1susauxb123.mdl to fix a bug. No DAQ restart required.

WP6324 Extend Remote Access controls to 24/7

Jonathan:

The RACCESS system is now operational 24/7 for the duration of ER10 and O2.

Testing new Hardware Injection data injestion

Keith, Dave, Jim:

New configurations of h1hwinj1 and h1guardian0 permit hw-injection users on h1hwinj1 to svn check-out the injection waveforms and schedules such that the guardian INJ_TRANS node can perform these injections. We had a minor local modification to the INJ_TRANS.py file which was removed and the guardian node code was updated to the latest SVN version. We discovered a slight discrepancy between the code and the schedule file which was resolved. System is ready for injection team to test.