Displaying report 1-1 of 1.
Reports until 21:36, Tuesday 15 November 2016
H1 ISC (ISC, OpsInfo)
sheila.dwyer@LIGO.ORG - posted 21:36, Tuesday 15 November 2016 - last comment - 12:27, Wednesday 16 November 2016(31525)
ASC changes, locking

Operator information:

I've added the Reduce RF9 modulation depth state back into the normal guardian path, but if you are having locklosses durring this state or right after you can try skipping it.  If you skip it, you might want to keep the beam diverters open so you can see that the SRC1 loops are OK (ie, the ratio of AS90/POP90 is staying reasonably high over the lock). You might need to open the SRC1 loops if you skip reducing RF9 modulation depth.  

I've also moved PR3 REFL WFS out of the normal path, so that it will be skipped for now if you just request nominal low noise. 

Comments related to this report
keita.kawabe@LIGO.ORG - 09:06, Wednesday 16 November 2016 (31534)

In the morning POPX DC PIT was routed to PRC2. Didn't make sense (POPX DC is controled by its own centering loop), so manually zero-ed it.

Should have had  no impact on anything as POPX DC is at least 4 orders of magnitude smaller than POPX RF over the entire frequency band.

Seems like this was puched in by hand last night.

Images attached to this comment
keita.kawabe@LIGO.ORG - 12:27, Wednesday 16 November 2016 (31542)

Combination of ASC-REFL_B_RF9I and 45I was routed to unused DC7 as a fake PRC2 on REFLB.

I measured the phase between this DC7 and PRC2 (which is POPX_I) in nominal low noise, and the YAW was out of phase for microseismic peak but not above 3Hz or so (first attachment left) though PIT was pretty good.

By changing the mixing ratio of REFLB RF9I and RF45I for YAW, the coherence between DC7 and PRC2 improves and the phase becomes saner (but never as good as PIT). The second attachment shows when the relevant input matrix components were [0.14, -0.08], i.e. 

DC7_YAW= 0.14*REFL_B_RF9I_YAW -0.08*REFL_B_RF45I_YAW.

(Nominally this was [0.14, -0.2].) The change was put in the guardian, I and Jenne were able to manually switch. Now PR3 is on REFL WFS instead of POPX.

This made ASAIR_B_RF90_I bouncier, but IFO seems to run. We'll run a2l and we'll also measure the sensing matrix

Images attached to this comment
Displaying report 1-1 of 1.