Reports until 00:20, Thursday 17 November 2016
H1 SEI (SEI)
travis.sadecki@LIGO.ORG - posted 00:20, Thursday 17 November 2016 - last comment - 09:40, Thursday 17 November 2016(31559)
H1 ISI CPS Noise Spectra Check - Weekly

Nothing appears out of the ordinary.  See attached screenshots.  FAMIS 6872.

Images attached to this report
Comments related to this report
jim.warner@LIGO.ORG - 09:40, Thursday 17 November 2016 (31565)OpsInfo

Travis' measurements are from July and October. I retook the measurements from a time from during one of his locks during the night and the CPS all look fine.

For the operators doing this task, ETMY ST2V2, the pink trace on the top of Travis' 3rd plot, is a bit elevated. That is the kind of issue that we are looking for with this task. Note that on my plot of the same chamber (also my third plot), all of the spectra are back down clustered around the black noise spec.

Images attached to this comment