Reports until 08:00, Thursday 17 November 2016
H1 General
travis.sadecki@LIGO.ORG - posted 08:00, Thursday 17 November 2016 (31560)
Ops Owl Shift Summary

TITLE: 11/17 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: TJ
SHIFT SUMMARY:  Relocking as my shift started.  Made it to NLN with no issues.
LOG:

8:32 Changed phase of PI mode 28 damping from -250 to 250.

8:36 Changed phase of PI mode 27 damping from 150 to 120.

8:45 Observing.

8:46 Accepted SDF diffs in MC2, PR2, ETMx, and ETMy Observe files per Betsy's request.  See screenshots of diffs prior to acceptance.

8:50 Out of Observing to run a2l.

8:55 Observing.

9:50 GRB alert. 

11:07 Out of Observing to run measurement for Sheila.

11:37 Lockloss.  Didn't abort Sheila's measurement soon enough.  Saved as /ligo/svncommon/lscSVN/iscmodeling/trunk/ALIGOH1/ASC_loops/Measurements/CHARD/2016_11_17_CHARD_P_OLG_SS_50W_low_noise.xml.

12:08 Changed phase of PI mode 28 damping from 250 to -250.

12:13 Changed phase of PI mode 27 damping from 120 to 90.

12:32 Observing.

13:17 Out of Observing to attempt to tweak SRM since the range seems to be diving.  Didn't seem to help much (or I didn't go far enough, but didn't want to get too risky). 

13:29 Ran a2l.

13:34 Realized I didn't turn off SRC1_P (according to latest instructions, this is what you are supposed to do) while tweaking SRM.  Turned off SRC1_P, tweaked SRM to no avail, and turned back on SRC1_P.  Turning on SRC1_P caused lockloss.  Guess I won't do that again.

13:43 Noticed that during ALS locking, the green Xarm power has come up to above 1 again.  Haven't seen that in a while.  Curious.  See screenshot for proof.

14:25 Observing.

15:15 GRB alert.

Images attached to this report