Comparing HAM2 ISI ISO_Z/RZ signals, HAM2 optic OSEM signals, and HAM2 and PR3 oplev signals

I've discovered HAM2 ISO_Z and ISO_RZ are well correlated to alignment changes in MC1 pitch and yaw, MC3 yaw, and anticorrelated with PR3 OSEM yaw.

It seems odd that the nm sized ISI ISO signals are showing up in the optic alignments, however this is what I find, and the optic OSEM alignment changes are not small.

I also looked at optical lever signals, and see that HAM2 and PR3 optical levers don't corellate to ISO or OSEM signals long-term.  HAM2 oplev does occasionally see a large ISI excursion, and correlates with multiple ISO DOFs.

Plot 1: MC1, MC3, and HAM2 ISI ISO_Z and ISO_RZ, 400 days

Plot 2: PR3 OSEM yaw, oplev yaw, HAM2 oplev yaw, HAM2 ISI ISO_RZ, 400 days

Plots 3 and 4: HAM2 oplev pitch, HAM2 ISO_RZ, ISO_X, 400 days

Summary:

Images attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 10:42, Thursday 17 November 2016 (31566)

Very interesting Cheryl!  A couple things of note and further info:

* There is an integration issue, FRS 5104 regarding the reversal of the HAM 2 & 3 ISI Oplev signals.  Doug says he changed the matrix, Suresh says it was the medm, Oreilly says the medm was addressed... still looks like a problem.

* "HAM2 oplev does occasionally see a large ISI excursion, and correlates with multiple ISO DOFs."  As soon as I saw these trends, I thought HEPI Pringle loops; I have a WP in to remove the Target Bias Restore for those DOFs, LHO aLog 31025.  To date, TJ and I have been unable to understand why these won't go quietly; Jamie is back in country and may solve this.  Still. interesting:

I guess I did not even look at the ISI but this restoration of the Target Bias into these AC couple loops literally distorts the HEPI platform until the Offset applied at restoration is easied as the band pass works.  I did not imagine that the ISI itself was in turn distorting but that is what is going on: The Pringle loop pulls or squeezes the Crossbeams in turn doing the same to the Support Tubes' relative position, in turn distorting the ISI Stage0.  This produces relative position changes at the CPSs and requires the ISO loop of the ISI to react.  See attached with the HEPI HP DOF output in the middle.  It makes sense that this would require alignment changes of the HAM2 Optics.  Further support to raise the lower ugf of these Pringle loops and stop the restoration of the Target Bias.

I'm not surprised that this might be affecting other DOFs too and therefore Pitch as well as the more obvious Yaw.  I will redouble my efforts to get these DOFs out of the Restore Bias list.

* Don't have anything to contribute as to the mamy other correlations reported.