Displaying report 1-1 of 1.
Reports until 11:16, Thursday 17 November 2016
H1 DAQ (CDS, DAQ)
keith.thorne@LIGO.ORG - posted 11:16, Thursday 17 November 2016 (31567)
Frame Data Rates at L1, H1 during ER10
I have determined new frame data rates for H1 and L1.  This was last updated before ER9 ( see aLOG 26706 )

I have only run the 'commissioning' rate scripts, as we have no science frames anymore

You can find the scripts (work at either site) at https://llocds.ligo-la.caltech.edu/data/keith.thorne/DataRates
You can find the L1 data at https://llocds.ligo-la.caltech.edu/data/keith.thorne/DataRates/2016-11-17/, the H1 data at https://lhocds.ligo-wa.caltech.edu/exports/keith.thorne/DataRates/2016-11-17/.

I have attached the summary data sheets in PDF and XLS formats as well as channel lists. These are all raw (uncompressed) rates.

Note: The H1 data rates are inflated (by 2.1 MB/s) by 8 64KHz channels from the SUS/OMC PI models.  These 'artificial' channels (set = 0) are no longer needed after RCG 3.1.1 and have been removed from L1.  This should be done on H1.

The raw H1 fast data size has shrunk from 56.19 to 55.20 MB/s (decrease of 1%).
The raw L1 fast data size has shrunk from 41.67 to 40.56 MB/s (decrease of 3%). Mostly removal of 6 64KHz channels.
The raw H1 fast data rates are now 7% larger than L1 fast data rates

From DAQ MEDM screens
H1 frames are ~1670 MB / 64 sec -> 26 MB/s
L1 frames are ~1400 MB / 64 sec -> 20 MB/s
Non-image files attached to this report
Displaying report 1-1 of 1.