Reports until 09:16, Friday 18 November 2016
H1 CAL (CAL, DetChar)
jeffrey.kissel@LIGO.ORG - posted 09:16, Friday 18 November 2016 - last comment - 15:33, Friday 18 November 2016(31589)
PCALX Roaming Calibration Line Frequency Changed from 4301.3 to 4501.3 Hz
Beautifully high duty cycle over the past few says. Nice work team! 

Current Schedule Status:
Frequency    Planned Amplitude        Planned Duration      Actual Amplitude    Start Time                 Stop Time                    Achieved Duration
(Hz)         (ct)                     (hh:mm)                   (ct)               (UTC)                    (UTC)                         (hh:mm)
---------------------------------------------------------------------------------------------------------------------------------------------------------
1001.3       35k                      02:00                   39322.0           Nov 11 2016 21:37:50 UTC    Nov 12 2016 03:28:21 UTC      ~several hours @ 25 W
1501.3       35k                      02:00                   39322.0           Oct 24 2016 15:26:57 UTC    Oct 31 2016 15:44:29 UTC      ~week @ 25 W
2001.3       35k                      02:00                   39322.0           Oct 17 2016 21:22:03 UTC    Oct 24 2016 15:26:57 UTC      several days (at both 50W and 25 W)
2501.3       35k                      05:00                   39322.0           Oct 12 2016 03:20:41 UTC    Oct 17 2016 21:22:03 UTC      days     @ 50 W
3001.3       35k                      05:00                   39322.0           Oct 06 2016 18:39:26 UTC    Oct 12 2016 03:20:41 UTC      days     @ 50 W
3501.3       35k                      05:00                   39322.0           Jul 06 2016 18:56:13 UTC    Oct 06 2016 18:39:26 UTC      months   @ 50 W
4001.3       40k                      10:00                   39322.0           Nov 12 2016 03:28:21 UTC    Nov 16 2016 22:17:29 UTC      days     @ 30 W (see LHO aLOG 31546)
4301.3       40k                      10:00                   39322.0           Nov 16 2016 22:17:29 UTC    Nov 18 2016 17:08:49 UTC      days     @ 30 W            
4501.3       40k                      10:00                   39322.0           Nov 18 2016 17:08:49 UTC                
4801.3       40k                      10:00  
5001.3       40k                      10:00
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:44, Friday 18 November 2016 (31611)DetChar
The 1083.7 Hz calibration line was turned OFF for a brief period (~1-2 hours) during this current 4501.3 Hz stretch. See LHO aLOG 31610 for details.
jeffrey.kissel@LIGO.ORG - 15:33, Friday 18 November 2016 (31618)
1083.7 Hz calibration line restored just after the lock loss at 2016-11-18 23:30 UTC.