Reports until 13:43, Friday 18 November 2016
H1 CAL (DetChar)
jeffrey.kissel@LIGO.ORG - posted 13:43, Friday 18 November 2016 - last comment - 15:33, Friday 18 November 2016(31610)
1083.7 Hz CAL Line Turned OFF Temporarily
J. Kissel

There's been renewed excitement about the relationship between the 1083.7 Hz calibration line and the surrounding, non-stationary PSL intensity/jitter noise coupling into the sensitivity. Namely, DetChar has seen glitching "around the 1 kHz calibration line." I had looked at this relationship briefly a few moons ago (see LHO aLOG 31035) and concluded these features were unrelated, and did not impact the use of the 1083.7 Hz line due to the intensity/jitter noise's convenient double-peak shape.  

I had thought I'd run an on/off test during that study, but rather than dig up the history, I find it easier to just run a new on/off test.

As such, I've turned OFF the 1083.7 Hz calibration line at Nov 18 2016 21:33:40 UTC, Nov 18 2016 13:33:40 PST, GPS 1163540037.

If we survive the EQ that's now hitting as I type this aLOG, I'll leave it OFF for an hour or two.
Images attached to this report
Comments related to this report
beverly.berger@LIGO.ORG - 14:06, Friday 18 November 2016 (31612)DetChar

The attached plot shows that the noisy behavior around the frequency of this line persists after it was turned off.

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 15:33, Friday 18 November 2016 (31617)DetChar
1083.7 Hz calibration line restored just after the lock loss at 2016-11-18 23:30 UTC.