joshua.freed@LIGO.ORG - posted 16:49, Sunday 25 January 2026 - last comment - 11:15, Wednesday 28 January 2026(88873)
SPI Pathfinder, Comprehensive Phase Noise measurements

J. Freed,

Continuing From 88293, I took phase noise measurements of waveform generators relevant to SPI pathfinder with two different methods. This first method is the standard method that LIGO uses which follows the BluePhase 1000 manual. I used this method to highlight the issues this method has in the context of SPI. The second method is a slight modification to the standard method which shows a lower noise floor in the area of interest for SPI.


First Method:  BluePhase1000_Setup.png (from LIGO-T2400324) Shows a simplified Phase noise measurements set up of what the BluePhase 1000 manual provides. A simple way to take phase noise measurements is to mix the signal from the Device under Test (DUT) with a reference device (REF) outputting the same frequency but at quadrature. Ideally, this mix outputs only the differential noise between the two devices. If the reference device has much better performance, then the mix ideally outputs only the DUT noise. In this method, a feedback loop is used to keep the REF at quadrature with the DUT. For the REF device, I used the 80MHz OCXO housed in LIGO-D1100663

OCXOComparisonTOCXO.png Shows the results from the first method, I used 3 different devices as the DUT; a 80MHz OCXO here at LIGO LIGO-S1000565, a SRS SG382, and a Keysight 33600A. The main thing of note is that OCXO is expected to have a much lower noise floor than any other device; however, below ~60Hz the noise is not limited by the different DUTs. Since the REF is another OCXO, I believe the feedback loop that keeps the REF device in quadrature is limiting measurements below 60Hz.  Since SPI is interested in phase measurements well below 60 Hz this first method will not work for taking phase noise measurements for SPI. Especially since SPI has both an 80Mhz and an 80MHz -4096Hz signal and LIGO  does not have a 80MHz -4096Hz OCXO to use as a ref. 


Second Method: PhaseNoiseSetUp.png shows the modified set up; where the REF device is the SRS SG382. This method puts the REF device at quadrature by setting it manually and holding it there through the 10MHz timing port created by dividing by 8 the 80MHz OCXO signal. Since both the REF and DUT are referenced to the same OCXO (or the DUT is the OCXO itself), ideally both devices will be held at quadrature bypassing the need for a feedback loop. In practice, I did notice a small amount of drift from quadrature over time. 

OCXOComparisonSRS.png Shows the results from this method. This graph shows both the OCXO and the Double Mixer have phase noise performances well below the noise performance of a typical waveform generator (Keysight) below 100Hz. Though combined with the last alog, still very much better than SPI requirments.


Difference: OCXOComparisonSRSOC.png (ignore the title on this plot) shows the mix of an 80MHz OCXO and the SRS using the two different methods to hold one at quadrature with the other. With the modified method, we are not limited as much below 60Hz, except those peaks at ~0.16Hz, ~0.45Hz, etc.. which I believe are caused by the divide-by-8, not the SRS; as the SRS measurement using the first method did not have these peaks. 


Extra:

OCXOComparisonFull.png Shows all measurements on one graph.

OCXOComparisonKey.png Shows that Keysight had strange harmonics at multiples of 5kHz but disappeared 12 hours later. 

Images attached to this report
Comments related to this report
joshua.freed@LIGO.ORG - 11:15, Wednesday 28 January 2026 (88944)

Applying the equation found in 88293 to the data in the modified method, we get a new plot Keyrad3.png that shows the SPI noise budget for phase noise of oscillators used in the build/install of SPI. We can come to the same conclusion as last time, that since SPI has a reference interferometer the noise drops significantly at low frequency (the area where SPI operates). The noise from SPI's selected oscillators for the build/install is expected to have a negligible effect on our noise budget.

Images attached to this comment
X1 DTS
joshua.freed@LIGO.ORG - posted 17:16, Monday 01 December 2025 - last comment - 11:36, Wednesday 10 December 2025(88293)
SPI Pathfinder, Phase noise measurements for Keysight 33600A waveform generator

J. Freed,

I took Phase noise measurements of the 2 channel Keysight 33600A waveform generator for its use in building SPI Pathfinder in the optics lab before install. Going only off of the phase noise graphs, it is sufficient as it shows comparable results to the SRS which had a phase noise considered to be good enough for SPI pathfinder.

Key.png Shows the phase noise results. C1, C2 are the phase noise results for Channel 1 and Channel 2 on the Keysight, respectively. (Set up shown below). Shown for comparison the SRS SG392, which was suggested as a possible frequency source for SPI. The last measurement shown is the direct measurement of phase noise between the 2 channels of the Keysight. This measurement reflects the intended use case of the Keysight for SPI. As we need 2 frequencies at slightly different frequencies locked to each other and SPI will be measuring the output phase difference. Note the 60Hz peak; most likely caused by unclean AC power. This is why we are not using an AC powered device in the final installation. 

Screenshot2025-12-01at50150 PM.png Shows the setup for C1, and C2. measurements. The SRS value was found with the same set up, just replacing the Keysight 33600A with a SRS. The C1-C2 is a direct measurement by plugging both channels into the BluePhase 1000. There is no 10MHz Ext back attachment in this measurment in order to best represent Keysight's theoretical performance in the optics lab.


 

Images attached to this report
Comments related to this report
joshua.freed@LIGO.ORG - 11:36, Wednesday 10 December 2025 (88457)

Edit to the other comment and the main post

After a discussion with Jeff, we figured the best course of action would be to have all the generators referenced to the same generator. In order to better compare all the results. As well as, redo the plot in the previous comment to better reflect SPIs requirements as the base standard rather than the other way around. 

PhaseNoiseSetUp.png Is a picture of the set up, it is similar to the previous tests except everything is referenced to the SRS. One thing I failed to mention in the previous tests and is not listed in the diagram is that the divide-by-eight goes into another Distribution Amp. before heading into the Ext. 10MHz of the function generators. Also note that the Double Mixer (DM) does not have an Ext 10MHz port. Instead it takes the 80MHz signal from the first differential amp; and a sin and cos 4096Hz signal from a CDS DAC through an AI chassis. (see 81593). Also note that the OCXO measurement took a pickoff from the first Distribution Amp instead of some sort of extra DoT. 

Keyrad2.png Is the graph of phase noise measurements of the Double Mixer (DM) D2400315, a LIGO 80 MHz OCXO D080702 (Which both DM and OCXO are used in the final SPI design), and a Keysight 33600A dual source waveform generator which will be used during the SPI build. The phase noise measurements were all referenced with a SRS SG382. Note that the BluePhase 1000 set up calculates values in dBc/Hz, to convert to a more directly useful value for SPI, rad/rtHz, I used the conversion:

[rad/rtHz] = sqrt(2) * 10^([dBc/Hz]/20)

The w/o. Ref. label is a separate reference from the SRS. In SPI, there is a reference interferometer that removes noise gained along each of the arms of the main SPI Mach-Zehnder. Mathematically speaking, this subtraction has an attinuation effect on our phase noise of:

Phase Noise = D/c * f * Phase noise(w/o. Ref.)

Where D is the length mismatch in the main arm between the reference and the main interferometers (or ~30m), c is the speed of light, and f is the frequency of the phase noise. Or put another way, the plots that have the label (w/o Ref.) are the direct measurements of the phase noise while plots without that label are the theoretical effect of the noise in our system. We will experimentally test this later once SPI is installed using injections; by altering the 4096Hz CDS filter bank for the DM. 

P.S. I have no idea why the OCXO noise is worse than the DM. We expected it to be better. A possibility is that since the DM measurements were taken more than a half a year ago, one of the devices was "just having a bad day" today. Investigating this, while interesting, is a lower priority than other tasks as the main goal of investigating the Keysight noise performance was achieved. 

Images attached to this comment
joshua.freed@LIGO.ORG - 13:57, Tuesday 02 December 2025 (88316)

Edits to previous post. Graph: X axis label should be 'Frequency offset from 80MHz (Hz)' and y-axis label should be 'dbc'

Keyradwref.png and Keyradworef.png are the requirements for the phase noise of our oscilator with SPI having and not having a reference interferometer respectivly. In the final SPI pathfinder install, we will have a reference interferometer giving us much less stringent requirements on our oscialtors phase noise. But during the build, it may be nessisary to run tests without a reference interferometer, I plotted the without reference interferometer if that situation ever does come up. 

Images attached to this comment
X1 DTS (ISC, OpsInfo, SQZ, SUS)
jeffrey.kissel@LIGO.ORG - posted 20:29, Monday 11 August 2025 (86311)
SPi Optomechanics: Picomotor Assembly Components
J. Kissel, C. Compton

Camilla and I took some pictures of what supply of picomotor assembly materials we (existing ICS Supply vs. what SPI) have and in what state of assembly they are in order to familiarize myself with the process of building up new assemblies. 

To the best of my knowledge, there's no assembly procedure. Instead, we have the Picomotor Fact Page (E2100196) [which I've, as of this aLOG, heavily updated / curated]:
    - A well-labeled exploded assembly drawing with only minor assembly errors, (Page 2 of D2100433)
    - a hand illustration from Rich on the wiring connections for an IXM100.C2, right-handed mount (D1400279) 
    - the expected two-motor pinout of the receiving D25M to 4x MM4F quadrapus cable (D1101516) 
    - Some instruction on how dis-mount and re-mount fully assembled picomotors (E2500163)
and thru a linear combination of these, you could fumble your way through it.

The picomotors themselves have evolved over the years as the original prefer vendor, New Focus, was bought out by Newport. 
:: First picture shows the difference between an old picomotor (left), and the modern 8301-UHV-KAP that we buy now (right). I've created D2500246 (as opposed to the old, non-specific E1000197) that captures the specific features of this model. The key differences between old vs. new being
    - The wires' insulation is kapton, not colored teflon
    - The wire lengths is a nice healthy 7 [in], not a short 2 [in] that required icky extension
    - The label of which wire is which is stamped into the metal (a "-" in the lower-left corner to indicate that the wire closest to that stamp is the negative lead, or "return") vs. indicated by color of wire.

:: Second picture shows the modern 8301-UHV-KAP picomotor by itself. Note, the "1" in 8301 indicates that we've chosen the 0.5" throw.

:: Third picture shows the cable unfurled and compared against the 1 [in] hole pattern of the optical table beneath the foil.

OK, now that you've gotten to know the raw picomotor, let's talk about cnonnectorizing and modifying it to suit our needs. We only have the old style picomotor fully assembled to picture as example, but it'll serve the purpose.

:: Fourth picture shows the real manifestation of Rich's artist impression of the fully connectorized two-motor system.

:: ECR E1400327 has us install a motion limiting shaft collar along the throw of the picomotor to limit the motion from the edge of its range where it's been found to get stuck. The collar was originally a custom D1400189 per -v1 of the ECR, but now it's a stock McMaster Carr shaft collar (6436k131, with the black-oxide steel #4-40 x 3/8 [in] L SHCS replaced with a stainless, otherwise identical, SHCS, 92196A108). The stock collar is then modified to be a bit thinner, per D1800220. Finally, to prevent the shaft collar from freezing against the picomotor body, we install a slip-on LIGO-cut kapton "washer" (D1400226; cut from 12 [in] x 12 [in] x 0.005 [in] sheet stock) around the threaded adjustment screw.
    - Fifth and Sixth pictures show how the shaft collar is shaved thinner,
    - Seventh picture shows the Kapton washers,
    - Eighth picture shows the collars assembled on the motor, and where the washer would be placed (these didn't have washers at the time of the picture, but we've since installed the on their to form a complete, albiet not-so-vacuum-compatible assembly).

:: Once connectorized, per Rich's drawing, to the 4-pin MMF connnector 803-003-07M6-4PN-598A, then the connector is secured to a custom L-bracket D1002763 via the connector's thumb screw. That L-bracket then secures to the optic mount's "other" 1/4"-20 mounting hole (with "the" 1/4"-20 mounting hole, 90-deg away, is presumably used to secure the mount to a post or breadboard). Note -- the L-bracket's thru-hole for the MM connector is keyed, but it's not sized for any feature on the actual connector, so you're free to orient the connector in any way in within the bracket. Of course, each socket connector on the legs of the quadrapus it'll connect to are much better keyed, so there's no worry of pin-clocking or anything nasty like that.
    - Ninth picture shows the D1002763 L-bracket. Note -- this a D1002763-v2 Type 1 bracket, so it's mounting hole is threaded for 1/4"-20 bolt (rather than Type 2 which has a thru-hole requiring a nut).
    - Tenth, Eleventh, Twelth, and Thirteenth pictures show how the MM connector is assembled on to that portion of the D1002763 L-bracket.

Finally, just because it came up during the pre-clean-and-bake inspection (see discussion in CNB:2225), 
    - Fourtheenth picture shows the inside of the 803-003-07M6-4PN-598A MM connector -- a  black plastic that Glenair calls a "High Grade Rigid Dialectric," without specifying the material (see table in Section 3.1 on page 2 of Mighty_Mouse_Series 80_performance-test-report-iaw-mil-dtl-810.pdf from T2500025). 
I mostly show the picture of the old connectorized picomotor system to indicate that we've indeed been using this connect and its inner material for a long time, and the Clean-and-bake process (T2100001) appears to be enough (see e.g. bake loads ICS:10543 and ICS:10557).

Images attached to this report
X1 DTS
joshua.freed@LIGO.ORG - posted 13:15, Thursday 29 May 2025 - last comment - 14:43, Friday 06 June 2025(84627)
SPI Double Mixer Finalization Part3

J. Freed,

Spur Problem

As discussed in part 1, the Double Mixer has good phase noise around the carrier frequency to about a 100Hz out where SPI operates, however, it also has signals every 4096Hz away from the carrier.  I had assumed that it was an issue relating to phase and amplitude mismatch on the phase delayer, but after adding attinuators to correct the missmatch, it helped, excepecially the 80Mhz + 4096Hz signal saw a ~15dB improvement. DM_Att.pdf. However, the double mixer still has large signals and the largest did not change with the addition of the attinuators.

I realize now that the problem lies with the mixers themselves as by the nature of a mixer they create spurs on the output. 

DM_Mixer.pdf Shows the output of a single mixer. Along with the expected 80MHz - 4096 Hz and 80MHz + 4096 Hz there is extra peaks which i believe is caused by the Spurs of the mixer. The largest spur is at 80Mhz + 12,288Hz. This spur is actually in phase with the main signal and is thus construtivly interfered at the power combiner. 

I do not know how to get rid of this spur as it is so close to the main carrier signal. For fun, I used a combination of Marki LC filter Design Tool and LTspice to simulate adding a filter to the end of the system to reduce the 80Mhz + 12,288Hz spur, but even an 8th order elliptical filter would only reduce the spur by ~0.04dB due to how close it is to the main signal. For fun I went to 20th order elliptic and it only reduced it by ~0.1dB. In addition, with nonstandard parts for a 20th order elliptic it got reduced by ~4dB. I am unsure of any other method to reduce the spur.


Double Mixer is a Single Sideband Mixer

I realize now that the basic design of the double mixer actually exists and is fairly common, it is called a Single Sideband Mixer (SSB mixer). Thanks to Brian, who gave me one of these mixers to test, I have something to compair the results  

DMvsIRM.pdf Shows a plot of the double mixer vs a SSB mixer. The SSB mixer is tuned to 80MHz+4096Hz as apposed to the Double Mixers 80MHz -4096Hz but comparisons can still be made. For starters, the double mixers 80Mhz+4096Hz sideband equivalent is much better in the double mixer vs the SSB. However this comes at the cost of the 80Mhz+12,288Hz sideband equivalent which is much better in the SSB. In summary, just based on this single graph, the double mixer is more likely to be better for SPI for 2 reasons. One, we have already found out that SPI would be senstive to the 80MHz+4096Hz sideband equivalent. And two, if there is a way to attinuate these spurs by filtering, the spur further away from the carrier could be more easily attinuated.


High order modes filtering

Ive already discussed that adding fliters does not help the area around 80MHz. However, it does help with higher order modes

DM_Filter.pdf Shows a plot of adding a MC80-10-4AA bandpass filter from Lark engenering that has a bandwidth of 10MHz and a center of 80MHz at different positions in the Double Mixer. The best place to put one seems to be just before the amplifier, not entirly sure if adding one is nessisary to SPI but it should be good for reduceing a possible noise source.

Non-image files attached to this report
Comments related to this report
joshua.freed@LIGO.ORG - 14:55, Friday 30 May 2025 (84674)

High-Order Mode Filtering

The MC80-10-4AA that I listed actually filters by reflections, which is not helping to remove those signals from going back into the mixer. If a filter is going to be added, something like the ZXLF-K151+ would work much better.

joshua.freed@LIGO.ORG - 14:43, Friday 06 June 2025 (84869)

I now realize a filter should be unnecessary as the AOMs are expected to have high insertion loss at frequencies not around 80Mhz, AOM-Tuneability.png, basically acting as a band-pass filter anyways. 

 

Images attached to this comment
X1 DTS
joshua.freed@LIGO.ORG - posted 14:55, Wednesday 28 May 2025 (84635)
Double Mixer Component Characterization (Finalization Part 2)

J. Freed

Contiuning the work from 84198 this alog is about characterizing the other components of the Double Mixer. D2400315


D2400296 PCB Board transimpedance amp

According to oscilloscope, the signals coming from PCB board are from J2 being cos and J3 being sin. The Vpp are 1.199V on J2 and 1.195V on J3. As before the phase measures are hard to get a read on as the phase measuremnt on the osciloscope says 90deg when I put J3 in the channel 1 position and 91deg when I put J2 in the channel 1 position. Instead I put a 4096 Hz signal generator on Channel 2 then put the of the sin and cos signals on channel 1.

D2400296 PCB Board transimpedance amp With a 1V from DAC

Relative Phase (deg)(+- 0.5) Amplitude (dBm) (+- 0.1)  
Cos(J2) 152.7 -30.6  
Sin(J3) -117.7 -30.6  
Difference 89.6 +- 0.7  

ZLW-1BR Mixer

The mixer data was collected at a range of values incase LO input power needed to be changed, however I would not recomened going below 4dBm LO as the isolation of all the ports falls gets worse the lower the power. The indivitual signals were colected on the Agilent 4396B with a BW of 10 Hz (best one the spectrum analizer allowed without giving an overload notification). While the Total power was given on the E4418A power meter. SRS SG382 was used for the LO power.

ZLW-1BR RF out power with a 1V IF input 3dBm LO power 4dBm LO power -4dBm LO power -7dBm LO power
At 80 MHz +- 4096Hz (dBm)(+- 0.1dBm) -4.0 -3.4 -10.8 -13.8
At 80 MHz (dBm)(+- 0.1dBm) -39.5 -38.0 -46.2 -49.2
Total (dBm)(+- 0.01dBm) -0.89 0.25 -7.52 -10.51

ZMSC-2-1BR Combiner

The combiner values were colected by using the Agilent 4396B to apply a sweep of values around 80 MHz. All values were the same in about a 10kHz span that was measured

ZMSC-2-1BR Combiner with -1 dBm on the port Relative Phase (deg)(+- 0.05) Power Drop (dB) (+ 0.01)
Port 1  -18.71 -3.12
Port 2 -18.65 -3.11
Difference 0.06 0.01

ZMDC-10-1+ Couplier

The couplier was characterized by applying a -1dBm from a SRS SG382 signal generator signal at 80MHz on the input port and reading off from the E4418A power meter. The other port not being measured was terminated. We do not care about relative phase so it was not collected

ZMDC-10-1+ Couplier Powers at 80MHz Power with -1dBm on Input (dBm)(+- 0.01)
Out -1.61
 Couple -12.50

 

X1 DTS
joshua.freed@LIGO.ORG - posted 10:43, Wednesday 28 May 2025 - last comment - 14:17, Thursday 29 May 2025(84621)
Double Mixer Amplifier Choise

J. Freed

The reason we picked the ZFL-500HLN amp for SPI's Double Mixer was that it was an amp that met requirements from minicircuts

-frequency range contains 80MHz (our operating frequency)

-Operates at voltage supplied by Low Noise Power(15V, 17V, 24V etc.)

-Has a P1dB well above our output power of 10dBm (to remove non-linearity)

-No heat sinks (to fit in a 1U chassis.) (This requirement actually doesnt matter, the ones discussed here are still the best even compaired to amps with heat sinks)

-sma connections

-Low noise

-Low gain (we only need ~8dB of amplification)

The ZFL-500HLN was chosen because it fit all those requirements, with the cavieat of having to attuniate before amplification (adding noise). Though if I am correct and the Low noise power board 5V Vcc port is capable of supporting a 63mA load, another option would be the ZX60-P105LN+ instead due to the lower gain and lower noise. This would remove the need for an attinuator before amplification but its low input return loss means alot of power is reflected back towards our mixers (Also causeing noise). So it becomes a pick your poison of adding noise by attinuating before amplification vs by reflections back into our mixers. In practice, I believe both would operate about the same. Will add a comment if something changes

Double-MixerAmpComparison.png shows a quick comparison of the 2 amps

Images attached to this report
Comments related to this report
joshua.freed@LIGO.ORG - 14:17, Thursday 29 May 2025 (84656)

Acording to this term definitions manual I found on minicircuts: 

"Directivity (active) is defined as the difference between isolation and forward gain in dB. It is an indication of the isolation of the source from the load, or how much the load impedance affects the input impedance and the source impedance affects the output impedance. The higher the active directivity (in dB), the better the isolation."

So directivity is just a measure of Isolation - Gain. Which isolation is just a measure of how much power is sent through the amp to the input port with power applied on the output. This would really only affect the amp when there is a large impedance mismatch on the output (load). If there is little to none, directivity doesnt really matter. But if it did come up, the ZFL-500HLN would do much better. The greater concern I believe for the ZX60-P105LN+ is the large input return loss, which is the power of the reflections off of the ports back the way it came. This would cause a standing wave on our input. To reduce it, we would have to add an attinuator on the input anyway. Probably less than the 10 dB attinuator which we currently have, but still something to consider. 

P.S. VSWR and Return Loss(RL) are the same thing with different units, the conversion between them is VSWRvsRL.png. A VSWR closer to 1 is better, while a higher return loss is better. Converting the  ZFL-500HLN aproximate 1.04:1 VSWR to Return loss gives 34.15dB. This means the reflections power are about 20dB greater on the ZX60-P105LN+. Really not sure if it is worth it excpecilly since mixers are sensitive to these reflections.

Images attached to this comment
X1 DTS
joshua.freed@LIGO.ORG - posted 12:46, Wednesday 30 April 2025 (84198)
SPI Double Mixer Finalization Part1

J. Freed

Last week, this week, and the next week, the goal is to finalize the double mixer design, drawings and chassis. M. Pirello. has begun the drawings while I finalize the design, and we will work on the layout as well as the front plate.

Currently 83439 shows that phase noise is good except for harmonics every 4096Hz away from carrier. While any frequency more than 100Hz around the carrier should not affect SPI some of them do have an effect (namely the 8192Hz harmonic), 81593 also shows an ocsiloscope reading of the output which shows how messy the signal looks. This as such this week the focus is on reducing those harmonics.


The Q2 transistor on the Low Noise Power Board failed last week, was replaced, then it popped and replaced again. The problem was diagnosed to be the power pins on the ZFL-500HLNB+ amp. The pins stick out and touched the metal casing of another minicircuit part causing a short on the +15V supply from the low noise power board. A temporary solution of electrical tape was use to isolate the pins while a more perminate isolation for the pins will be there when it is finalized

AGBW.jpg Shows that the Agilent 4396B in spectrum analyzer mode gives less information with a smaller resolution bandwidth. The higher resolution bandwidth shows more harmonics with greater power on said harmonics. I do not know why this is, which is why I will be looking at phase noise when trying to improve harmonics.


The Agilent 4396B in network analyzer mode was used to take transfer functions of the double mixer phase delayer, IMG_1472.jpg shows the set up. The source power was 13dBm, the central frequency was 80MHz. The Span and Resolution Bandwidth were both 40kHz but changeing these values did not change much as the amplitude and phase was relativly flat around 80 MHz. A 10dB attinuator was added to the output to remove the overload message on port B that appered around 7dBm input power when I was incresing power to 13dBm.This is ok as I could calibrate the machine by replacing the phase delayer with a addaptor that let the signal go straight through. This calibration became my (0dBm 0deg) reference.  I took measuments of one port of the phase delayer at a time while terminating the other. 

Table 1: Output TF of the Phase Delayer
  Gain (dB) +- 0.01 Phase (deg) +- 0.1
Port 1 -3.31 -84.6
Port 2 -2.93 3.1
Difference 0.38 -87.7

This is slightly off from what was hoped for with (0dBm -90deg) difference. SPI has some 0.5dB attinuators as well as 1dB attinuators. Due to the attinuators not being their listed value at 80 MHz, Two 0.5dB attinuators on port 2 and one 1dB attinuator on port 1 seems to nearly correct the power differnece.

Continuing from here is characterizing the mixers, the summer, and RF couplers to gain inisight on reducing the harmonics.

 

Images attached to this report
X1 DTS
joshua.freed@LIGO.ORG - posted 17:04, Tuesday 18 March 2025 - last comment - 20:31, Tuesday 18 March 2025(83439)
Double Mixer Focus on the 8kHz Sideband

J. Freed

Today I collected 2 phase noises, first phase noise is of the 80 MHz OCXO after it has gone through an RF distributer. The reference was the SRS SG382 at 80MHz

The second is of the Double Mixer again but with an extra focus on the 8192Hz sideband.The reference was agian the SRS SG382 at 80MHz-4096Hz

These tests was done with the direct plug in method without using a PLL. This requires both the device under test and the reference device to be at quadrature. Normally a PLL is required to keep them there, however since both devices are connected to the LIGO timing system in some way,  a PLL is unnecessary to keep them locked in quadrature. To put them in quadrature I just lined them up on an oscilloscope best I could then added 90 deg by adjusting the phase on the SRS.  I bypassed the internal amp of the BluePhase1000 for all tests.

DM_vs_RF.pdf Is a plot of the two phase noises, as seen, the low frequency noise (<2Hz) has these humps. I now attribute these to the RF distributer causeing a shape change in the pure sin wave signal. 

RF_Distributer_Signal.jpg Shows how the RF distributer has a not exact sin wave (Yellow) compared to the SRS Pure tone (Blue)

DM8kSideband.pdf Shows a close up on the 8k sideband that will also couple into our SPI output 

Images attached to this report
Non-image files attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 20:31, Tuesday 18 March 2025 (83446)

The measured curve looks very similar to the SRS SG382 spec at 100MHz. There is no reason to believe the SG382 is better than the OCXO.

X1 DTS
joshua.freed@LIGO.ORG - posted 18:28, Tuesday 21 January 2025 (82391)
Double Mixer Update

J. Freed

 

Before the hoidays as shown in 81658, the Double Mixer had large phase noises at 4096Hz that were thought to be caused by phase offest difference in the Double Mixer. Thanks to Marc Pirello for the suggestion and help to manually adjust the phase difference by extending the wire lengths inside the double mixer. 

DM_PN2.pdf Shows the lower 4096Hz peak in the path adjust(green) as compared to the no path adjust (blue) and both compared to an independant SRS (orange). The harmonics are still large so  DAC output had a ~5kHz low pass applied but with negledgable improvement. Investigation was ongoing when I went on holiday. 

 

Today I plugged in the double mixer into a network analyzer to see the power spectrum density of the signal 

DM_NA_WIDE.pdf Shows that although the DM has better noise floor, the harmonics of the double mixer are quite a bit worse in the Power spectral desnity than shown in phase noise DM_PN2. The best result (shown) was with NO added length. Unsure why this is. 

DM_NA_NARROW.pdf Besides that the signal has a fairly pure tone, though this is limmited by the resolution.

Investigations ongoing 

Non-image files attached to this report
X1 DTS
joshua.freed@LIGO.ORG - posted 17:09, Friday 06 December 2024 (81658)
Initial Noise results for Double Mixer

J. Freed, 

 

Update on Double Mixer Progress 81593, Proceded through step 2a of the double mixer test plan T2400327. Initial results are sugesting a possible noise improvemnt compaired to the other options in the area of interest for SPI.

DM_PN1.pdf Shows the phase noise test run in step 2a of the Double Mixer Test plan. While not a true 1-to-1 comparison of the phase noise performance of the double mixer compered to other options (step 2b is for that), it shows that adding the double mixer into this system (except for the peaks) improves phase noise performance by a factor of 2-5 from 100 Hz to 20 kHz. Of note, there is a large peak are centered around the 4096 Hz that is of interest to SPI. As there was only a cursory attept to properly phase match the signals in the internals of the double mixer for this initial test, the 4096 Hz sideband was not properly removed. 

A possible cause of this phase miss match is our phase delayer inside the double mixer (ZMSCQ-2-90B) causes a phase delay of about 89.82 degrees at 80MHz and not the 90 degrees we are expecting.

Possible fixes

The very low frequency (<0.05Hz) contains DC noise caused by the external phase mismatch of the double mixer and the reference source for the phase noise measurments. It is not an indication of double mixer drift and there has not been yet investigations in drift.

Non-image files attached to this report
X1 DTS
joshua.freed@LIGO.ORG - posted 18:55, Monday 02 December 2024 (81593)
Double Mixer Topology initial Test

J. Freed,

 

On Wednesday Nov 20th, the Double Mixer topology for SPI D2400315-x0 was taken, and it works how we intended as a way to gerenrate a 80MHz - 4096Hz signal it to but with alot of noise.

DMPrototype.png Is a diagram of the Double Mixer Design

DM_First_Test.png Is a diagram of the test done on the Double Mixer, this inital test was just to check that the Double Mixer produces the expected output signal frequency, as such, the amplifier was ignored. 

DM_FT_Result.png Shows the output on the scope.  Blue is the double mixer output. White is a reference of SRS SG382 (sync with 80 Mhz OCXO via 10 MHz Timing) with a frequency of 79,995,904 Hz and power of -0.91 dBm. The SRS signal, timed with the OCXO, and the double mixer correctly locks with eachother. This gives credance that this design will work for the goal of the double mixer; a 79,995,904 Hz signal frequency locked to a 80MHz OCXO. However there is a lot of noise in the double mixer signal. An ongoing investigation is currently underway to find and reduce this noise.

ZMSCQ_Wave_Shape.png Shows a possible source of the noise, the Double Mixer requires phase delayer for the Sin path, we used a MiniCircuts ZMSCQ-2-90B for this. I tested the ZMSCQ-2-90B by puggining the input of the signal and the signal from the 2 ports into osciloscope. I split off the input signal with a Minicircuts ZMSC-2-1BR+ (Summer/Splitter) and I had to normalize input power pickoff in postprocessing by a factor of 0.68 due to the power difference. The results show that the output of the ZMSCQ-2-90B has a sligtly different shape than what was plugged in. With the delay port (orange) having a slight "hump" on the rise. Will retake with a faster osciloscope, as the signal is very noisy.

The investigation is continuing with the next step of checking the double mixer output signal with a network anaylizer to check the frequencies around 79,995,904 Hz. A Phase noise measurement would also work with the caviot that the phase adjust to destructivly interfere the double mixer signal with the reference signal would have to be adjusted manually.

Images attached to this report
X1 DTS
joshua.freed@LIGO.ORG - posted 13:27, Wednesday 30 October 2024 - last comment - 11:12, Thursday 31 October 2024(80923)
SPI, First step of characterizing double mixer

J. Freed

I followed Step 1 of the double mixer test plan in T2400327 under "1. Characterize frequency references." 

PNSPIDACTestStand.pdf Shows the results in dBc/Hz. And PNSPIDACTestStandrad.pdf shows the result in rad/sqrt(Hz).

Besides the 80MHz standard reference there were 2 devices under test, the IFR 2023A and the SRS SG382. These two devices went under 3 tests involving different combinations of

1. Timing to a 10MHz frequency standard produced by the 80MHz Standard. (Time Standard)

2. PLL locking to a different 80MHz frequency ref through the tune in port. (Lock)

During this process it was assumed that the 80MHz standard and the added 80MHz ref would have a simmilar noise profile as they come from a simmialar OCXO.

A 4th test was added to the Time Standard/No Lock test which used the SR785s internal high pass filter (-3dB at 0.16Hz) to remove some of the DC components from the test. This is because the results of the initial test were inconclusive as the noise floor of the SR785 was too high. The noise floor was too high because there was a DC signal that caused the input range of the SR785 to be about 20dB. The high pass filter, removed the DC signal, lowering the noise floor at the cost of signals below about 0.2Hz not being accurate. We believe this is caused by the fact that while the PLL locking can be controled (tries to lock signals to destructivly interfere so to lower output power for Phase noise tests), there was no control by the Time Standard on phase differences between oscilators. As Time Standard/ No lock, showed the best results above 0.06Hz and is closest to the SPI set up design, this fact may be important when doing futher tests.

Between IFR and SRS, the SRS showed better phase noise performance below 7kHz. While IFR showed better performance above 7kHz. As such, SRS shows more promise in SPIs phase noise range of interest 0-4096Hz.

 

 

Non-image files attached to this report
Comments related to this report
joshua.freed@LIGO.ORG - 11:12, Thursday 31 October 2024 (80972)

After a talk with Jeff what is really important to show is the TIme Standard/Lock which is the 80 MHz OCXO, IFR and SRS which we believe is most represntative of phase noise

These are, one at a time, locked to another 80 MHz REF OCXO. In this it was assumed that the 80 MHz OCXO and the 80 MHz REF OCXO would produce the same phase noise, as such contribute equally to the output phase noise. As such the output was manually halved to represent the only the 80 MHz OCXO. As stated before these measurments also had a Time Standard (sometimes called time sync) where the 80 MHz OCXO is synced to the site's 1PPS. And the IFR and SRS have a 10MHz signal time standard signal that was produced by the 80 MHz OCXO divided by 8 and sent into the back of the devices.

PNSPIDACTestStandrad(sync_lockOnly).pdf Shows only the results of the Time Standard/Lock, which we believe to be the most represntative of the phasenoise of these devices. 

Since it was assumed that the two OCXOs would have the same phase noise, this also makes our noise limit equal the OCXO. As such, it can be seen from this graph that we are at the noise limit in measuring the phase noise of the IFR and SRS between 0.1Hz-10Hz. 

Non-image files attached to this comment