Couple of locklosses may have caused by CARM running away

I suspect this is the result of the broken tidal servo?

Images attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 07:37, Saturday 19 November 2016 (31646)

I reverted the REDTRIG on/off threshold back to where they were 2 days ago. I can see some outputs now. The threshold were set to 8000 (ON) and 5000 (OFF) previously (as mentioned in alog31573). Below I attached a plot showing LSC-X_ARM_MON being 0 through the entire two lock stretches.