TITLE: 11/19 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing
INCOMING OPERATOR: Jim
SHIFT SUMMARY: I've been skipping CLOSE_BEAM_DIVERTERS afraid that it would cause the lockloss as Sheila reported in alog31635 when the tidal servo wasn't working. I skipped beam diverters during the most recent lock even WITH the tidal servo working, that was just a habit. I could have gone through PR3 REFL WFS step. Tidal servo didn't work most of my shift until I reverted the tidal trigger thresold (see alog31646)
LOG:
11:19 Ran a2l and went to Observe
12:58 Verbal alarm outputs OMC DCPD Saturation followed by lockloss.
14:17 Another Lockloss. CARM ran away.
15:15 At DC_READOUT. Following procedure from Terra's alog 31593. Turned off PI gains.
15:17 Turned PI gains back on, then run a2l. Sorry I read instruction in wrong order. It's late for me.
15:22 a2l done. Zeroed all PI gains and moving on.
15:31 Running another a2l at NLN. PI gains are still 0.
15:37 a2l done. Set intent bit.
15:48 -3000 gain to PI mode 28
15:49 +5000 gain to PI mode 27
15:51 +3000gain to PI mode 26
15:53 -5000 gain to PI mode 27, then flipped back to 5000