Reports until 19:00, Saturday 19 November 2016
H1 ISC
sheila.dwyer@LIGO.ORG - posted 19:00, Saturday 19 November 2016 (31653)
PR3 back on REFL WFS

Cheryl and I swtiched to REFL WFS at about 1:34 UTC, and have been locked this way for about an hour without any problems so far.  The secondary microseism is around 0.4 to 0.5 um/second, velocities where we previously had trouble switching to REFL WFS.  You can see in the attached striptool that the transition did make the AS90 build ups a little less stable.  

After this was locked for about a half hour, I made some SRCL injections because of the higher SRCL coherence with this new alignment. It seems like we can do better for the noise around 80-100 Hz by using split FF for now, I've put in the gains of -1.1 for the low frequency filter and -1.3 for the high frequency filter.  (see attached screenshot)  These settings are in the guardain now.  

We closed the beam diverters without incident and are ready to go back to observe. 

Images attached to this report