kyle.ryan@LIGO.ORG - posted 08:01, Sunday 20 November 2016 - last comment - 19:44, Sunday 20 November 2016(31661)
Annulus ion pump out of range
Can't id exact unit remotely or from memory but think this is on the Diagonal Volume.  I think that all AIPs on the diagonal are low hour so hopefully this will be an easy electronics swap? 

Comments related to this report
john.worden@LIGO.ORG - 09:31, Sunday 20 November 2016 (31663)

This one is labeled IBM AIP 192 (also LY-IBM)  - perhaps the 2K input MC tube?? Did we mislabel these?

The other red one is HAM12 on the 2K volume.

Images attached to this comment
chandra.romel@LIGO.ORG - 19:44, Sunday 20 November 2016 (31673)

The one labeled IBM is on 2K volume, but there is no pump connected to annulus volume right now, which is why it's been red on vacuum GUI. That volume was pumped down and capped off at a valve. HAM 12 on vacuum GUI is actually HAM 11 (same with HAM7/8). We should fix wiring so they read right.