Displaying report 1-1 of 1.
Reports until 16:04, Sunday 20 November 2016
H1 General
jim.warner@LIGO.ORG - posted 16:04, Sunday 20 November 2016 - last comment - 23:39, Sunday 20 November 2016(31669)
Shift Summary

TITLE: 11/20 Day Shift: 16:00-24:00 UTC

STATE of H1: Observing

SHIFT SUMMARY:  Lost a 30 hour lock from an earthquake. Jeff, Kiwamu and Darkhan were here doing calibration stuff. Having problems relocking, can't get past noise-tunings. ITMY swing continues to annoy after lock losses.

20:00 Jeff and crew start calibration measurements

21:00 6.4 earthquake in Argentina breaks lock

21:30 Corey brings a tour through

22:00 Robert in and out of LVEA, setting up PEM injections

Comments related to this report
kiwamu.izumi@LIGO.ORG - 19:26, Sunday 20 November 2016 (31672)

Cheryl, Kiwamu,

Executing each line of NOISE_TUNINGS, we spotted typo in which MICH FF and SRCL FF1 were selecting a wrong set of digital filters. In particular, MICHFF was the worst -- it didn't use the AC coupling filter, resulting in a jolt to ITMs. We set them to the ones that had been used in the previous 30 hour lock stretch (31653). Cheryl will test this to see if the situation is better.

sheila.dwyer@LIGO.ORG - 23:39, Sunday 20 November 2016 (31674)
Sorry that was my mistake.