Displaying report 1-1 of 1.
Reports until 23:48, Sunday 20 November 2016
H1 SUS (SUS)
cheryl.vorvick@LIGO.ORG - posted 23:48, Sunday 20 November 2016 - last comment - 16:03, Monday 21 November 2016(31675)
ITMY appears to be swinging in pitch at 0.55Hz thoughout H1 locks

Maybe this is known, but I didn't find an alog showing this feature of ITMY.

Plot 1: ITMY

OSEMs LF and RT have a peak at 0.55Hz throughout the long lock yesterday, T0 = 11/19, 16:00UTC, 750 averages

The peak in the LF and RT OSEMs seems to suggest the optic is swinging at 0.55Hz in pitch all the time, and that that swinging gets kicked up at lock loss.

Plot 2: ITMY, ITMX, ETMY, ETMX, OSEMs LF and RT, all optics

The peak at 0.55Hz in OSEMs LF and RT is unique to ITMY.

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 09:21, Monday 21 November 2016 (31680)OpsInfo
It's not really helpful, because we don't yet have a solution, but here's the aLOG where this problem has been explored: LHO aLOG 31404. I have no suggestions as of yet on how to fix it, other than re-designing the loops to add more gain (read: *any* gain) at this frequency.

Hugh is studying how far back in time this problem has persisted (it's been a problem since at *least* Oct 28), in hopes to find some sort of coincident hardware/electronics activity to blame. But so far, no dice.
sheila.dwyer@LIGO.ORG - 16:03, Monday 21 November 2016 (31701)OpsInfo

Jeff K, Sheila, Jenne, Evan

While we were having an EQ, we took a quick look at what is wrong with ITMY.  

Since Cheryl pointed out that this motion is seen in LF and RT, we became suspicous of a problem with top mass V and R damping.  Indeed, there was a "bounce" filter engaged in ITMY top mass V damping which must have been a mistake.  Once we turned this off the OLTF of the vertical damping looks verry similar between ITMX and ITMY.  With this filter on ITMY damping was garbage.  

I accepted the change in SDF. We also noticed while doing this that the top mass actuator state for ITMX was 1, while the rest of the quads were in state 2, so we switched that.  The large peak at 0.55 Hz that Cheryl aloged is gone now, and hopefully we won't have the problem with long long ringdowns on ITMY. 

Images attached to this comment
Displaying report 1-1 of 1.