While at the End Station doing weekly fluid level checks, the HEPI tripped off due to a fluid level trip. Two Things:
1) I have the fluid level trip point set pretty close to the running level to keep the mess minimal in the event of a leak. 2) The pressure wash task of the roof ladder had the jar wide open with an air temperature, what, mid 30s?
I did just manage to record the fluid level before the trip and it was down 1/16". I surmise the cold air reduced the volume of the fluid enough to trigger the level switch.
I've lowered the trip point about 1/4" so this should not be an issue for some time, 1/16" was just a little too little head room. Let's keep the door as closed as possible in extreme weather.
The system recovered just fine.