John Z., Aaron V. John restarted the primary GDS pipeline at GPS time 1163860820 +- several minutes, and I restarted the redundant pipeline at GPS time 1163887460. The latency was ~5-10 seconds and the CPU usage is ~70%, both usual. This restart picked up gstlal-calibration-1.0.8, which includes these changes: - Addition of option --kappas-default-to-median to replace rejected kappas with last good median instead of default - Bug fix to prevent/reduce latencies due to bad dataValid flags - Addition of option --demodulation-filter-settle-time to allow filter to settle before accepting computed kappas. A new filters file is also being used. See this aLOG for information on the filters: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=31712