16:00 Kyle is at EX as reported by Nutsinee
16:02 Joe D out to LVEA to do his weeklies.
16:02 Richard and Gerardo to EX to gt RGAs started WP
16:13 Joe out and He , Bubba amd Chris are headed to EY
16:30 Krishsna out to floor to re-center CS BRS WP6355
16:36 Jason and Peter out to floor to turn of DBB WP6317
16:37 Hugh headed to Ends to do HEPI fluid checks
16:39 Vending machine maintenance on site - Coca Cola
16:46 Lockloss due to maintenance incursions. Guardian set to down.
16:48 Jason and Peter out
16:49 Kyle back
16:49 TJ trying some new SEI code on HAM6 for pringle mode WP6341
16:56 noticed Fast Shutter check request from DIAG_MAIN. Set LOCKLOSS_SHUTTER_CHECK to LOW_ARM_POWER.
17:01 Chandra in LVEA woking on Ion pump HAM11. Gerardo out to join her.
17:03 H0:VAC-MY_CP4_LT250_PUMP_LEVEL_PCT alarm
17:04 EY HEPI DIFF pressure trip while Hugh working on it. Telephone call had me manually adjust output tweak on pressure servo
17:11 Alfredo to CS and out buildings to reinstal electronics for infrasound mics WP6343
17:15 reset HEPI pump pressure servo at EY a second time. Untripping watchdogs.
17:30 LN2 load on site
17:35 Corner station tripped. We think it may be that Alfredo settting the infrasound mic down in the Biergarten close to the STS did it. Expectin the same from the end stations when he gets to them.
17:44 put FAST_SHUTTER node into manual and brought to DOWN. Returned to AUTO and ran INIT in ISC_LOCK.
17:45 untripping corner
18:08 Duat monitor 6 in LVEA - Yellow alarm. Looks like it reached a threshold of 7920 cts
18:11 Karen back from EY and headed into LVEA.
18:16 Kyle turning on his noise sources at BSC8
18:20 Guardian reboot WP6337
18:28 Richard and Alfredo going to check on RGA network connection and then to the vault
18:37 Re dust alarms monitor 10 - .3=74020 .5=27820
18:39 BS HEPI WD trip - reason uncertain
18:41 dust monitor 6 RED alarm - .3=11270
18:48 Paradise water delivery on site
19:10 Joe back from End and heading into LVEA to complete weekly tasks
19:21 Joe out of LVEA
19:29 PSL Dust alarm .3=1520 .5=730
19:43 TJ restarting HAM6 guardian node to revert back to original config.
20:02 restarted Ops workstation at Carlos's request
20:20 BRS back on at end stations
20:20 begin initial alignment
20:36 Green arms aligned and offloaded. Waiting for Sheila to do INPUT_ALIGN as she has a new filter to try.
20:38 resuming IA
20:39 Jeff and Cheryl have re-aligned IMs
20:46 Richard to EY to put anemometer on roof.
21:22 Begin main locking sequence
22:55 OMC node is repaired(it seems) DC readout achieved. a2l script started and the stopped due to Sheila noticing something fishy in DARM.
00:06 running a2l
00:07 handing off to Corey