Displaying report 1-1 of 1.
Reports until 18:02, Tuesday 22 November 2016
H1 CAL (CDS)
jeffrey.kissel@LIGO.ORG - posted 18:02, Tuesday 22 November 2016 (31746)
Second DARM Calibration Oscillator Hooked up to CAL-CS Calibration Line Output
J. Kissel
WP 6338

We've implemented the same bug fix to the CAL-CS front-end model that LLO has that connects the H1:CAL-CS_TDEP_DARM_LINE2_DEMOD_OSC into the sum for calibration line output of the CAL-CS model, shipped over to the OMC model to be added in just after the LSC-DARM banks. This oscillator is occasionally used for testing, so we need it hooked up. 
Check out LLO aLOG 29521 for screenshots of the model change.

This change merely required an svn update of the 
/opt/rtcds/userapps/release/cal/common/models/
CAL_CS_MASTER.mdl
to absorb the changes that Joe has already made, followed by an installation and restart of the h1calcs model. No DAQ restart was required, but the DAQ was restarted for various other changes made this morning.
Displaying report 1-1 of 1.