Second DARM Calibration Oscillator Hooked up to CAL-CS Calibration Line Output
J. Kissel
WP 6338

We've implemented the same bug fix to the CAL-CS front-end model that LLO has that connects the H1:CAL-CS_TDEP_DARM_LINE2_DEMOD_OSC into the sum for calibration line output of the CAL-CS model, shipped over to the OMC model to be added in just after the LSC-DARM banks. This oscillator is occasionally used for testing, so we need it hooked up. 
Check out LLO aLOG 29521 for screenshots of the model change.

This change merely required an svn update of the 
/opt/rtcds/userapps/release/cal/common/models/
CAL_CS_MASTER.mdl