Displaying report 1-1 of 1.
Reports until 12:46, Wednesday 23 November 2016
H1 OpsInfo (ISC, OpsInfo)
jenne.driggers@LIGO.ORG - posted 12:46, Wednesday 23 November 2016 (31787)
New troubleshooting guide for H1

I have created a new troubleshooting guide for H1, in preparation for O2.  It is available at G1602280 (too big for alog, so won't add it here also).  Attached here is the overview page that in the document has clickable links to each section.

My vision for this is that it is a go-to document when things aren't working as smoothly as they should be.  I try to provide specific instructions on what to do, but also enough information that Detector Engineers, Operators and anyone else can start looking deeper and debug problems on their own.  Text throughout the guide is clickable, so that you can jump to the section that you need. 

I encourage others to add to the document, or point me to well-written wiki pages / alogs with detailed instructions so that I can add to the document.  For example, both the PI and violin mode damping "instructions" in the guide actually just point you to the very well written wiki pages on those topics.  There are 19 sections so far, but I'm sure that I've missed some, and that others will come up, so please let me know or modify the document yourself if you find something!

Images attached to this report
Displaying report 1-1 of 1.