Reports until 09:59, Monday 28 November 2016
H1 CAL (DetChar, INJ, OpsInfo)
jeffrey.kissel@LIGO.ORG - posted 09:59, Monday 28 November 2016 (31901)
PCALX Roaming Calibration Line Turned Back ON -- Restarting Schedule at 1001.3
J. Kissel, E. Goetz

The roaming PCALX calibration line was turned off for hardware injections over the weekend (LHO aLOG 31861). It looks like we have enough data at 5001.3 Hz (started at LHO aLOG 31738), so I'm restarting the line at the low frequency end (1001.3 Hz) and re-running through the lower half of the schedule in order to gather data at 30 [W] instead of the inconsistent 25 & 50 [W]. I include the old completed schedule for reference as well, just in case we don't get enough data before the run starts.


Frequency    Planned Amplitude        Planned Duration      Actual Amplitude    Start Time                 Stop Time                    Achieved Duration
(Hz)         (ct)                     (hh:mm)                   (ct)               (UTC)                    (UTC)                         (hh:mm)
---------------------------------------------------------------------------------------------------------------------------------------------------------
1001.3       35k                      02:00                   39322.0           Nov 28 2016 17:20:44 UTC
1501.3       35k                      02:00                   39322.0           
2001.3       35k                      02:00                   39322.0           
2501.3       35k                      05:00                   39322.0           
3001.3       35k                      05:00                   39322.0           
3501.3       35k                      05:00                   39322.0           
4001.3       40k                      10:00                   39322.0           
4301.3       40k                      10:00                   39322.0                
4501.3       40k                      10:00                   39322.0           
4801.3       40k                      10:00                   39222.0           
5001.3       40k                      10:00                   39222.0           


Frequency    Planned Amplitude        Planned Duration      Actual Amplitude    Start Time                 Stop Time                    Achieved Duration
(Hz)         (ct)                     (hh:mm)                   (ct)               (UTC)                    (UTC)                         (hh:mm)
---------------------------------------------------------------------------------------------------------------------------------------------------------
1001.3       35k                      02:00                   39322.0           Nov 11 2016 21:37:50 UTC    Nov 12 2016 03:28:21 UTC      ~several hours @ 25 W
1501.3       35k                      02:00                   39322.0           Oct 24 2016 15:26:57 UTC    Oct 31 2016 15:44:29 UTC      ~week @ 25 W
2001.3       35k                      02:00                   39322.0           Oct 17 2016 21:22:03 UTC    Oct 24 2016 15:26:57 UTC      several days (at both 50W and 25 W)
2501.3       35k                      05:00                   39322.0           Oct 12 2016 03:20:41 UTC    Oct 17 2016 21:22:03 UTC      days     @ 50 W
3001.3       35k                      05:00                   39322.0           Oct 06 2016 18:39:26 UTC    Oct 12 2016 03:20:41 UTC      days     @ 50 W
3501.3       35k                      05:00                   39322.0           Jul 06 2016 18:56:13 UTC    Oct 06 2016 18:39:26 UTC      months   @ 50 W
4001.3       40k                      10:00                   39322.0           Nov 12 2016 03:28:21 UTC    Nov 16 2016 22:17:29 UTC      days     @ 30 W (see LHO aLOG 31546 for caveats)
4301.3       40k                      10:00                   39322.0           Nov 16 2016 22:17:29 UTC    Nov 18 2016 17:08:49 UTC      days     @ 30 W          
4501.3       40k                      10:00                   39322.0           Nov 18 2016 17:08:49 UTC    Nov 20 2016 16:54:32 UTC      days     @ 30 W (see LHO aLOG 31610 for caveats)   
4801.3       40k                      10:00                   39222.0           Nov 20 2016 16:54:32 UTC    Nov 22 2016 23:56:06 UTC      days     @ 30 W
5001.3       40k                      10:00                   39222.0           Nov 22 2016 23:56:06 UTC    Nov 28 2016 17:20:44 UTC      days     @ 30 W (line was OFF and ON for Hardware INJ)