PSL Weekly Famis

Frontend Watch is GREEN

HPO Watch is GREEN
 
PMC:
It has been locked 0.0 days, 2.0 hr 30.0 minutes (should be days/weeks)
Reflected power is 13.8044380062 Watts and PowerSum = 77.7908359675 Watts.
 
FSS:
It has been locked for 0.0 days 0.0 h and 38.0 min (should be days/weeks)
TPD[V] = 3.29815664619V (min 0.9V)
 
ISS:
The diffracted power is around 3.55612046431% (should be 5-9%)
Last saturation event was 0.0 days 2.0 hours and 30.0 minutes ago (should be days/weeks)
 
 
Possible Issues:
(Be sure to look into these, as they will not be printed in the report)
PMC reflected power is high
Comments related to this report
jeffrey.kissel@LIGO.ORG - 17:02, Monday 28 November 2016 (31937)DetChar, PSL
For the record, these up-times are low because we've just gone through a PSL incursion to install new, stiffer, better damped, mounts for PZTs on the PSL periscope mirrors (aLOG pending, for now see ops report in LHO aLOG 31917). No problem here.