Reports until 12:07, Tuesday 29 November 2016
LHO VE
kyle.ryan@LIGO.ORG - posted 12:07, Tuesday 29 November 2016 - last comment - 09:51, Friday 02 December 2016(31970)
Energized PT180, exposed PT180 to site vacuum volume, PT180 now in nominal configuration -> indicated pressure now valid
Kyle R., Gerardo M., Richard M. 

(completes WPs #6332 and #6360)

Initial pressure indication shortly after being energized was 3 x 10-3 torr (PT180 is a "wide-range" gauge).  If real, this would be higher than expected for the ~17 hrs. of accumulation -> "burped" the accumulated gas into the connected pump setup while Gerardo monitored its pirani gauge -> it gave no indication of a change and remained steady at 1.9 x 10-3 torr which is as expected.  Neither gauge is calibrated in this pressure region of interest.  Noted PT180 responded as expected to being combined with local turbo -> Isolated temporary local pump setup, valved-in (exposed/combined) PT180 to site vacuum volume, vented locally mounted turbo and removed from PT180 hardware -> Installed 1 1/2" O-ring valve and 2.75" CF to NW40 adapter in place of the turbo and pumped to rough vacuum the space between the two 1 1/2" pump port valves.  

Comments related to this report
chandra.romel@LIGO.ORG - 16:12, Tuesday 29 November 2016 (31981)

So far the bake looks successful. Pressure prior was 40 nTorr. Now it's at 8.5 nTorr and still falling.

Images attached to this comment
chandra.romel@LIGO.ORG - 09:51, Friday 02 December 2016 (32101)

After a hopeful initial outcome, looks like gauge is drifting back up.

Images attached to this comment