Reports until 01:10, Wednesday 30 November 2016
H1 INJ (INJ)
adam.mullavey@LIGO.ORG - posted 01:10, Wednesday 30 November 2016 - last comment - 11:01, Wednesday 30 November 2016(31998)
Coherent CBC Injections

I've scheduled a CBC injection to begin at 9:20 UTC (1:20 PT).

Here is the change to the schedule file:

1164532817 H1L1 INJECT_CBC_ACTIVE 1 1.0 Inspiral/{ifo}/imri_hwinj_snr24_1163501538_{ifo}_filtered.txt

I'll be scheduling more shortly.

Comments related to this report
adam.mullavey@LIGO.ORG - 01:47, Wednesday 30 November 2016 (32000)

I've scheduled another two injections. The next one is a NSBH inspiral scheduled at 10:30 UTC (2:30 PT) and the following one is another BBH scheduled for 11:40 UTC (3:40 PT).

Here is the update to the schedule file:

1164537017 H1L1 INJECT_CBC_ACTIVE 1 1.0 Inspiral/{ifo}/nsbh_hwinj_snr24_1163501314_{ifo}_filtered.txt

1164541217 H1L1 INJECT_CBC_ACTIVE 1 1.0 Inspiral/{ifo}/imri_hwinj_snr24_1163501530_{ifo}_filtered.txt

The xml files can be found in the injection svn in the Inspiral directory.

adam.mullavey@LIGO.ORG - 11:01, Wednesday 30 November 2016 (32023)INJ

All three of these scheduled injections were successfully injected at LHO. The first two were coincident with LLO, the third wasn't injected at LLO as the L1 IFO was down at the time. The relevant section of the INJ_TRANS guardian log is attached.

Non-image files attached to this comment