Violin Damping - ETMX mode4 damped with many changes, ETMY and ITMX small changes

ETMX changes:

mode 1 gain: 50 -> 100
mode 2 gain: 0 -> 150, FM3 engaged (+60deg), FM5 disengaged (N505.710)
mode 3 gain: 100 -> 300, FM3 engaged (+60deg)
mode 4 gain: set by guardian -> -120
mode 5 gain: 30 -> 100, FM3 engaged (+60deg)
mode 6 gain: -100 -> -300
mode 7 gain: 150 -> 300
mode 8 gain: 50 -> 200

ETMY changes:

mode 6 gain: -24 -> -60

ITMX changes:

mode 1 FM3 engaged (+60deg)

Bounce Mode Damping: I increased the gains

ETMY gain = 0.3
ETMX gain = 0.3
ITMX gain = 0.5
ITMY gain = 0.5

After relocking, the ETMX changes didn't work exactly as they did in my lock - picture attached.