Reports until 14:05, Thursday 01 December 2016
H1 SUS
jenne.driggers@LIGO.ORG - posted 14:05, Thursday 01 December 2016 (32080)
Selected violin mode gains not-monitored

In order to go to Observe, JeffK noticed that some of the violin mode gains change lock-to-lock.  We looked in the guardian, and the violin damping mode generator state uses a function called adjustDamperGain() which lowers the damping gain of selected modes if the peak is too high. 

For all of the modes which are currently under this adjuster's control, I have not-monitored the gain channel for that mode.  The attached screenshot is of the guardian code that is adjusting the gain, and serves as a list of all the modes whos gain I've not-monitored. 

If we comment some of these adjusters out, or add more, we'll need to re-visit the list of not-monitored channels.

Images attached to this report