Reports until 18:05, Thursday 21 June 2012
H2 ISC
keita.kawabe@LIGO.ORG - posted 18:05, Thursday 21 June 2012 (3210)
refcav locking trouble

Earlier in the day we had a hard time locking refcav, and I've found that the voltage supply for the RF amplifier was current limited.
 I set it to maximum and the problem was gone.