Reports until 18:43, Saturday 03 December 2016
H1 General (DetChar, OpsInfo)
edmond.merilh@LIGO.ORG - posted 18:43, Saturday 03 December 2016 - last comment - 15:47, Monday 12 December 2016(32152)
H1 Intention Bit Temporarily out of Observe

02:26UTC Verbal Alarm said Intention bit set to Commissioning. Checking the SDF i found that the EX ECAT PLC2 was blinking. Below is a screen cap of the channel that was blinking. DIAG_MAIN was also showing a message  in the log seen in the other screenshot. The channel listed in the SDF and the Message in the DIAG_MAIN correlate in terms of time of occurence and subsystem (ALS). Some troublesome ALS channels were unmonitored last night by Keita. Looking back to his aLog, this appears to be a straggler. I was able to Un-Monitor this channel and reset the Intention bit.

02:27UTC Intention bit set to Observe

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 15:47, Monday 12 December 2016 (32487)GRD, ISC

Good Catch, Ed.  

I am going to paste the channel name in here so it can come up during a search (because we had the same issue with the Y-arm a week later).  The channel in question here (which is in Ed's snapshot) is:

H1:ALS-X_FIBR_LOCK_TEMPERATURECONTROLS_ON