Displaying report 1-1 of 1.
Reports until 12:13, Monday 05 December 2016
H1 ISC
daniel.sigg@LIGO.ORG - posted 12:13, Monday 05 December 2016 (32191)
Adding a 16 kHz DAQ channel to monitor the RIN in reflection

This implements ECR E1600359. The new DAQ channel is named H1:LSC-REFL_A_RIN_OUT_DQ.

The calibration is done for a locked interferometer and directly relates to the RIN measured by the ISS, see alog 31399.

An updated medm screen is attached. It is accessible from the LSC Overview.

Images attached to this report
Displaying report 1-1 of 1.