Adding a 16 kHz DAQ channel to monitor the RIN in reflection

This implements ECR E1600359. The new DAQ channel is named H1:LSC-REFL_A_RIN_OUT_DQ.

The calibration is done for a locked interferometer and directly relates to the RIN measured by the ISS, see alog 31399.

An updated medm screen is attached. It is accessible from the LSC Overview.