J. Kissel Continuing the schedule of roaming PCALX line. We'll run this line for one more day, so that we get two points at 4001.3 Hz with a 30 [W] IFO to check consistency between the two repeats of the schedule, and then shut off the line until further notice. Frequency Planned Amplitude Planned Duration Actual Amplitude Start Time Stop Time Achieved Duration (Hz) (ct) (hh:mm) (ct) (UTC) (UTC) (hh:mm) --------------------------------------------------------------------------------------------------------------------------------------------------------- 1001.3 35k 02:00 39322.0 Nov 28 2016 17:20:44 UTC Nov 30 2016 17:16:00 UTC days @ 30 W 1501.3 35k 02:00 39322.0 Nov 30 2016 17:27:00 UTC Nov 30 2016 19:36:00 UTC 02:09 @ 30 W 2001.3 35k 02:00 39322.0 Nov 30 2016 19:36:00 UTC Nov 30 2016 22:07:00 UTC 02:31 @ 30 W 2501.3 35k 05:00 39322.0 Nov 30 2016 22:08:00 UTC Dec 02 2016 20:16:00 UTC days @ 30 W 3001.3 35k 05:00 39322.0 Dec 02 2016 20:17:00 UTC Dec 05 2016 16:58:57 UTC days @ 30 W 3501.3 35k 05:00 39322.0 Dec 05 2016 16:58:57 UTC Dec 06 2016 21:09:56 UTC ~15:00 @ 30 W 4001.3 40k 10:00 39322.0 Dec 06 2016 21:09:56 UTC 4301.3 40k 10:00 39322.0 4501.3 40k 10:00 39322.0 4801.3 40k 10:00 39222.0 5001.3 40k 10:00 39222.0 Frequency Planned Amplitude Planned Duration Actual Amplitude Start Time Stop Time Achieved Duration (Hz) (ct) (hh:mm) (ct) (UTC) (UTC) (hh:mm) --------------------------------------------------------------------------------------------------------------------------------------------------------- 1001.3 35k 02:00 39322.0 Nov 11 2016 21:37:50 UTC Nov 12 2016 03:28:21 UTC ~several hours @ 25 W 1501.3 35k 02:00 39322.0 Oct 24 2016 15:26:57 UTC Oct 31 2016 15:44:29 UTC ~week @ 25 W 2001.3 35k 02:00 39322.0 Oct 17 2016 21:22:03 UTC Oct 24 2016 15:26:57 UTC several days (at both 50W and 25 W) 2501.3 35k 05:00 39322.0 Oct 12 2016 03:20:41 UTC Oct 17 2016 21:22:03 UTC days @ 50 W 3001.3 35k 05:00 39322.0 Oct 06 2016 18:39:26 UTC Oct 12 2016 03:20:41 UTC days @ 50 W 3501.3 35k 05:00 39322.0 Jul 06 2016 18:56:13 UTC Oct 06 2016 18:39:26 UTC months @ 50 W 4001.3 40k 10:00 39322.0 Nov 12 2016 03:28:21 UTC Nov 16 2016 22:17:29 UTC days @ 30 W (see LHO aLOG 31546 for caveats) 4301.3 40k 10:00 39322.0 Nov 16 2016 22:17:29 UTC Nov 18 2016 17:08:49 UTC days @ 30 W 4501.3 40k 10:00 39322.0 Nov 18 2016 17:08:49 UTC Nov 20 2016 16:54:32 UTC days @ 30 W (see LHO aLOG 31610 for caveats) 4801.3 40k 10:00 39222.0 Nov 20 2016 16:54:32 UTC Nov 22 2016 23:56:06 UTC days @ 30 W 5001.3 40k 10:00 39222.0 Nov 22 2016 23:56:06 UTC Nov 28 2016 17:20:44 UTC days @ 30 W (line was OFF and ON for Hardware INJ)