Reports until 08:54, Wednesday 07 December 2016
H1 PSL
edmond.merilh@LIGO.ORG - posted 08:54, Wednesday 07 December 2016 - last comment - 08:57, Wednesday 07 December 2016(32301)
PSL Weekly 10 Day Trends - FAMIS #6125

WeeklyXtal - Powers in D3 and D4 show decline that is consistent with humidity trends. D2 power appears to be fairly steady. D1 power appears to have increased slightly.

WeeklyLaser - OSC_BOXHUM  is on the decline. Generally everything looks ok here.

WeeklyEnv - As noted in the WeeklyXtal comments, humidity has dropped notably at all sensors.

WeeklyChiller - Normal. If anything to comment on, there appears to be a very marginal increase in pressures at times with an equally corresponding increase in  some headflow.

Images attached to this report
Comments related to this report
jason.oberling@LIGO.ORG - 08:57, Wednesday 07 December 2016 (32302)

Concur with Ed's analysis, everything looks normal.