J. Kissel for S. Karki WP #6368 I've moved the PCALX roaming line, its long duration sweep, from 4001.3 Hz to 4301.3 Hz. See schedule status below. Since it looks like we'll have the duty cycle to just finish the schedule within a week, I'm just going to continue to re-gathering the highest frequency data. As such, Sudarshan has something consistent and straightforward with which to work instead of data with a bunch details or qualifications. Frequency Planned Amplitude Planned Duration Actual Amplitude Start Time Stop Time Achieved Duration (Hz) (ct) (hh:mm) (ct) (UTC) (UTC) (hh:mm) --------------------------------------------------------------------------------------------------------------------------------------------------------- 1001.3 35k 02:00 39322.0 Nov 28 2016 17:20:44 UTC Nov 30 2016 17:16:00 UTC days @ 30 W 1501.3 35k 02:00 39322.0 Nov 30 2016 17:27:00 UTC Nov 30 2016 19:36:00 UTC 02:09 @ 30 W 2001.3 35k 02:00 39322.0 Nov 30 2016 19:36:00 UTC Nov 30 2016 22:07:00 UTC 02:31 @ 30 W 2501.3 35k 05:00 39322.0 Nov 30 2016 22:08:00 UTC Dec 02 2016 20:16:00 UTC days @ 30 W 3001.3 35k 05:00 39322.0 Dec 02 2016 20:17:00 UTC Dec 05 2016 16:58:57 UTC days @ 30 W 3501.3 35k 05:00 39322.0 Dec 05 2016 16:58:57 UTC Dec 06 2016 21:09:56 UTC ~15:00 @ 30 W 4001.3 40k 10:00 39322.0 Dec 06 2016 21:09:56 UTC Dec 07 2016 18:50:09 UTC ~20:00 @ 30 W 4301.3 40k 10:00 39322.0 Dec 07 2016 18:50:09 UTC 4501.3 40k 10:00 39322.0 4801.3 40k 10:00 39222.0 5001.3 40k 10:00 39222.0 Frequency Planned Amplitude Planned Duration Actual Amplitude Start Time Stop Time Achieved Duration (Hz) (ct) (hh:mm) (ct) (UTC) (UTC) (hh:mm) --------------------------------------------------------------------------------------------------------------------------------------------------------- 1001.3 35k 02:00 39322.0 Nov 11 2016 21:37:50 UTC Nov 12 2016 03:28:21 UTC ~several hours @ 25 W 1501.3 35k 02:00 39322.0 Oct 24 2016 15:26:57 UTC Oct 31 2016 15:44:29 UTC ~week @ 25 W 2001.3 35k 02:00 39322.0 Oct 17 2016 21:22:03 UTC Oct 24 2016 15:26:57 UTC several days (at both 50W and 25 W) 2501.3 35k 05:00 39322.0 Oct 12 2016 03:20:41 UTC Oct 17 2016 21:22:03 UTC days @ 50 W 3001.3 35k 05:00 39322.0 Oct 06 2016 18:39:26 UTC Oct 12 2016 03:20:41 UTC days @ 50 W 3501.3 35k 05:00 39322.0 Jul 06 2016 18:56:13 UTC Oct 06 2016 18:39:26 UTC months @ 50 W 4001.3 40k 10:00 39322.0 Nov 12 2016 03:28:21 UTC Nov 16 2016 22:17:29 UTC days @ 30 W (see LHO aLOG 31546 for caveats) 4301.3 40k 10:00 39322.0 Nov 16 2016 22:17:29 UTC Nov 18 2016 17:08:49 UTC days @ 30 W 4501.3 40k 10:00 39322.0 Nov 18 2016 17:08:49 UTC Nov 20 2016 16:54:32 UTC days @ 30 W (see LHO aLOG 31610 for caveats) 4801.3 40k 10:00 39222.0 Nov 20 2016 16:54:32 UTC Nov 22 2016 23:56:06 UTC days @ 30 W 5001.3 40k 10:00 39222.0 Nov 22 2016 23:56:06 UTC Nov 28 2016 17:20:44 UTC days @ 30 W (line was OFF and ON for Hardware INJ)
Note, PCALX was briefly turned OFF during this 4301.3 Hz stretch. See LHO aLOG 32323.
The Pcal to DARM ratio for these individual lines were calculated using SLM Tool and the result is tabulated below. The Cavity pole and the optical gain on the last column are eyeballed measurement from the CalMon Tool . These time dependent corrections havenot been applied to the sensing function analysis yet.
Freq Start Time End Time FFT Real Complex Coh CC Pole (O. Gain)
---------------------------------------------------------------------------------------------------------------------
1001.3 30-Nov-2016 09:16:44 30-Nov-2016 13:47:04 10 0.022149 -0.358814 0.999589 346.05(0.9863)
---------------------------------------------------------------------------------------------------------------------
1501.3 30-Nov-2016 17:28:11 30-Nov-2016 19:36:18 10 -0.017951 -0.109817 0.999943 346.05(0.9863)
---------------------------------------------------------------------------------------------------------------------
2001.3 30-Nov-2016 19:36:53 30-Nov-2016 21:01:35 10 -0.015679 -0.044511 0.999391 346.05(0.9863)
---------------------------------------------------------------------------------------------------------------------
2501.3 02-Dec-2016 07:52:51 02-Dec-2016 20:16:47 30 -0.011385 -0.020594 0.998321 347.69(0.9703)
---------------------------------------------------------------------------------------------------------------------
3001.3 04-Dec-2016 02:27:58 05-Dec-2016 00:00:17 30 -0.007719 -0.010563 0.999057 347.06(0.9614)
---------------------------------------------------------------------------------------------------------------------
3501.3 06-Dec-2016 02:27:26 06-Dec-2016 06:10:11 30 -0.005708 -0.005431 0.988492 350.70(0.9793)
3501.3 06-Dec-2016 10:36:18 06-Dec-2016 15:03:35 30 350.70(0.9793)
---------------------------------------------------------------------------------------------------------------------
4001.3 12-Nov-2016 17:20:18 12-Nov-2016 20:49:17 60 -0.004374 -0.003211 0.996350 350.00(0.9966)
4001.3 12-Nov-2016 09:48:25 12-Nov-2016 16:40:53 60 350.00(0.9966)
---------------------------------------------------------------------------------------------------------------------
4301.3 18-Nov-2016 05:20:00 18-Nov-2016 12:44:49 60 -0.003607 -0.002212 0.985922 345.04(0.9748)
4301.3 17-Nov-2016 14:26:40 17-Nov-2016 17:20:13 60 347.00(0.9730)
4301.3 17-Nov-2016 08:56:40 17-Nov-2016 11:07:35 60 347.00(0.9730)
---------------------------------------------------------------------------------------------------------------------
4501.3 20-Nov-2016 05:00:00 20-Nov-2016 13:24:30 60 -0.003366 -0.002162 0.990728 350.76(0.9985)
4501.3 19-Nov-2016 15:40:00 19-Nov-2016 23:48:16 60 350.21(1.0017)
---------------------------------------------------------------------------------------------------------------------
4801.3 22-Nov-2016 07:43:20 22-Nov-2016 16:01:44 60 -0.002883 -0.001369 0.959987 346.89(0.9890)
4801.3 21-Nov-2016 15:20:00 21-Nov-2016 18:22:20 60 346.71(0.9979)
4801.3 21-Nov-2016 04:36:40 21-Nov-2016 09:28:48 60 346.71(0.9979)
---------------------------------------------------------------------------------------------------------------------
5001.3 25-Nov-2016 07:43:17 25-Nov-2016 14:52:54 60 -0.002634 -0.000904 0.973928 348.94(0.9625)
5001.3 27-Nov-2016 11:44:40 27-Nov-2016 18:04:12 60 345.48(0.9724)
---------------------------------------------------------------------------------------------------------------------
More detailed Analysis.