Coherent Stochastic Hardware Injection

I've scheduled a coherent stochastic injection for 00:20 UTC (16:20 PT). It will take 13 mins. The update to the schedule file is:

1165191617 H1L1 INJECT_STOCHASTIC_ACTIVE 1 1.0 stoch/Waveform/SB_ER10_{ifo}.txt

Comments related to this report
evan.goetz@LIGO.ORG - 16:29, Wednesday 07 December 2016 (32324)
The PINJ_TRANSIENT_GAIN change from 0 to 1 for the stochastic injection knocked us out of observing intent before the start of the injection. We made this channel now unmonitored and went back to observing before the injection began.
adam.mullavey@LIGO.ORG - 16:48, Wednesday 07 December 2016 (32330)INJ

The stochastic waveform was successfully injected into both IFOs. The log file for H1 INJ_TRANS is attached.