changes to make locklosses less violent

While we were out of observing I did a few quick things to try to make our locklosses a little gentler.  (part of WP 6391)

First, I set limits on the TR QPD pit and yaw signals of 2, rather than 100 which were the previous limits.  These shouldn't go above 1 if we are locked, but can become large after a lockloss and send large signals to the suspensions through the soft loops.  I accepted the new values in SDF so we could go back to observe.

I did a little bit of work on the down state of the ISC_LOCK guardian, and loaded some of the changes.  

We can see if this makes things better for the next lockloss.  

Comments related to this report
sheila.dwyer@LIGO.ORG - 12:09, Monday 16 January 2017 (33341)

A comment to make this alog easier to search.  This is related to Borja's study of signals durring locklosses, and Anamaria's entry about locklosses at LLO