HW injection schedule file and Inspiral directory updated, Xend Pcal line stopped in anticipation of HW injections

EvanG, RickS

The HWinj schedule file on h1hwinj1 was updated as well as the Inspiral directory.

The Schedule file was loaded in the Guardian. (by Travis in the control room).

The HF Pcal line at Xend was stopped at 6:41 UTC (by Travis in the control room).

Six CBC injections are schedule to go in tomorrow morning, starting at 6 AM PST and separated by 70 minutes.

We will want to restart the Pcal line at Xend when the injections are finished, around noon tomorrow (Friday).

Comments related to this report
travis.sadecki@LIGO.ORG - 22:59, Thursday 08 December 2016 (32377)

Screenshot of PCal X line prior to being turned off.

Images attached to this comment
travis.sadecki@LIGO.ORG - 23:30, Thursday 08 December 2016 (32378)

I also had to accept the SDF diffs for turning this line off in order to go to Observing.  See screenshot.

Images attached to this comment