Reports until 09:23, Friday 09 December 2016
H1 CAL (CAL)
aaron.viets@LIGO.ORG - posted 09:23, Friday 09 December 2016 (32389)
New GDS filters for LHO with correct inverse sensing function Foton file
I have made a filters file for LHO that includes the corrections made by Evan G. and Jeff K. (see https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=32329 ). The filters were made using revision #3929 of the calibration SVN and can be found here:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/GDSFilters/H1GDS_1165269650.npz

The parameters used to make these filters are:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/Common/params/IFOindepParams.conf
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/params/H1params.conf
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/params/2016-11-12/H1params_2016-11-12.conf
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/params/H1_TDparams_1165269650.conf
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/Scripts/CAL_EPICS/D20161122_H1_CAL_EPICS_VALUES.m

Several plots are attached:
1) h(f) spectrum from CAL-CS and GDS 
2) Ratio of spectra (GDS / CAL-CS)
3) Residual correction filter
4) Control correction filter

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=32329
Images attached to this report
Non-image files attached to this report