As soon as H1 went up, L1 went down.
EQ levels subsided so immediately proceeded with locking (only hitch was a low X-arm for ALS & this was remedied with a slight TMSx tweek). Made it to NLN with no issues.
I saw we had quite a few Test Points open on the CDS Overview (some were 20+ for some PEM front ends). I went about running a TP Clear on all of them (except H1CALEX which had 1). In case you were interested the frontends I did a TP Clear on, had the following DCUIDs: 24, 30, 31, 75, 50, 54, 55, 60, 98, 99, 80, 118, 10, 19, 121, 88, 89, 91, & 84.
Shortly thereafter, I hammered down the MODE28 PI before it got raucous (phase sign flip).
Range is hovering around 75Mpc.
Transitioned OBSERVATORY_MODE from EARTHQUAKE to OBSERVING.
Looking at Violin Mode peaks on DARM, we have: