Reports until 09:42, Monday 12 December 2016
H1 DAQ (CDS)
james.batch@LIGO.ORG - posted 09:42, Monday 12 December 2016 - last comment - 10:38, Monday 12 December 2016(32470)
Reboot h1tw0 to force fsck
The /trend file system on h1tw0 became corrupt this morning about 6:05 AM PST. Rebooted computer to force unmount and fsck of file system. Many errors were discovered and repaired. It appears there may be a bad drive in the RAID, it is being replaced.  The daqd process is also dying when it encounters an improperly sized file, we will probably just remove it. 
Comments related to this report
james.batch@LIGO.ORG - 10:38, Monday 12 December 2016 (32475)
There were 9445 corrupted files in /trend/minute_raw which needed to be removed.