chandra.romel@LIGO.ORG - posted 09:45, Monday 12 December 2016 - last comment - 09:58, Monday 12 December 2016(32471)
CP3 & CP4 overfill
9:40 am local
Took about 30 sec. to overfill CP3 & CP4 each. Both nominal LLCV settings were a bit high based on exhaust pressure (non zero) and TC readings prior to fill. I've lowered CP3 to 18% and CP4 to 37%.
Comments related to this report
chandra.romel@LIGO.ORG - 09:53, Monday 12 December 2016 (32472)
Lowered CP4 LLCV further to 36% open.
35%