Reports until 16:13, Tuesday 13 December 2016
H1 General
jeffrey.bartlett@LIGO.ORG - posted 16:13, Tuesday 13 December 2016 (32536)
Ops Day Shift Summary

Ops Shift Log:12/13/2016, Day Shift 16:00 – 00:00 (08:00 - 16:00) Time -  UTC (PT)

State of H1: IFO Locked at NOMINAL_LOW_NOISE. Power is 28.5W. Range is 68.7MPc.
Intent Bit: Observing
Support: Jenne, Peter K., Ed,  
Incoming Operator: Patrick
Shift Summary: Completed routine maintenance and tried relocking without running Initial Alignment. Could not get past DRM_1F. Decided to run Initial Alignment. Completed the alignment and relocked the IFO on the first attempt. Now at NOMINAL_LOW_NOISE.  Power at 28.4W. Range is 75.7MPc. We have been locked in Observing mode for the past 2 hours.  

 

Activity Log: Time - UTC (PT)

16:00 (08:00) Take over from Corey
16:12 (08:12) Joe – Going into the LVEA to charge batteries
16:13 (08:13) Dropped out of Observing for maintenance
16:30 (08:30) Kyle – Vent annulus volume between K2 & MC – Connect pump (WP #6386)
16:33 (08:33) Joe – Out of LVEA
16:35 (08:35) Joe – Going to End-X & Mid-X facilities equipment checks
16:50 (08:50) Filiberto – Going to End-Y for Beckhoff safety system work (WP #6389)
16:58 (08:58) Bubba – Going into the LVEA – crane work for 3IFO
16:59 (08:59) Karen – Going to End-Y for cleaning
16:59 (08:59) Christina – Going to End-X for cleaning
17:03 (09:03) Turn off BRS at End-X & End-Y for maintenance
17:19 (09:19) Joe – Back from the X arm stations
17:20 (09:20) Joe – Going to End-Y & Mid-Y for facilities equipment checks
17:22 (09:22) Bubba – Out of the LVEA
17:24 (09:24) Norco on site to deliver N2
17:27 (09:27) RotoRooter on site – Escorted by Bubba
17:32 (09:32) Beverage service on site to fill vending machines
17:36 (09:36) Norco – On site delivery of N2 to CP1
17:47 (09:47) Lost Lock – Maintenance
17:52 (09:52) Marc – Going to Mid-X for power supply work (WP #6361)
17:59 (09:59) Christina – Finished at End-X
18:00 (10:00) Peter – Going into PSL to dress up Ref Cavity alignment
18:09 (10:09) Chandra – Finished at End-X
18:12 (10:12) Betsy – Running charge measurements at both End Stations
18:25 (10:25) Karen – Cleaning in the LVEA
18:40 (10:40) Joe – Back from Y arms
19:00 (11:00) Jeff K. – Taking tour into the LVEA
19:03 (11:03) Marc – Back from Mid-X
19:17 (11:17) Joe – Going into the LVEA to unplug battery chargers
19:28 (11:28) Joe – Out of the LVEA
19:29 (11:29) Karen – Out of the LVEA
19:45 (11:45) Jeff B. – Going into the LVEA to look for dust monitor comptroler
19:48 (11:48) Jim B & Carlos – Going into the LVEA to look for dust monitor comptroler
20:00 (12:00) Filiberto – Back from End-Y
20:07 (12:07) Start lock acquisition
20:12 (12:12) Kyle – Out of the LVEA
20:15 (12:15) Switch ISI Config to WINDY
20:24 (12:24) Peter – Check that phone in the H2 Enclosure is off
20:34 (12:34) Peter – Out of the LVEA
20:50 (12:50) Start Initial Alignment
21:40 (13:40) Start Locking
21:57 (13:57) HFD on site to check alarm panel
22:02 (14:02) IFO Locked at NOMINAL_LOW_NOISE
22:03 (14:03) Set intent bit to Observing
23:00 (15:00) Marc – Going to Mid-Y
23:40 (15:40) Marc – Back from Mid-Y
23:55 (15:55) Ran A2L template – No problem with A2L noted
00:00 (16:00) Turn over to Patrick