TITLE: 12/16 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 73.1215Mpc
INCOMING OPERATOR: Travis
SHIFT SUMMARY: No changes to note since mid shift summary. 
LOG:
01:10 UTC Brief notification that HWSX code stopped running.
01:40 UTC Out of observing to run a2l.
01:48 UTC a2l done. No errors reported. Back to observing.
02:04 UTC EY started constantly saturating.
02:44 UTC Out of observing. Changed gain for H1:SUS-ETMY_L2_DAMP_MODE10 from 100 to 0.02. Turned off FM1 and turned on FM9 and FM10 (Settings at Dec 15 2016 08:46:51 UTC from conlog test machine). 4.7kHz mode has come down and saturations have stopped.
02:59 UTC Accepted SDF differences. Back to observing.