Chandra lifted the lead for TE252A. Kyle put the CP4 LLCV into PID and disabled. The script to fill CP4 was run: vacuum@vacuum1:/ligo/home/patrick.thomas/svn/scripts$ python cp4_fill.py 70 -60 3600 Starting CP4 fill. TC A error. LLCV enabled. LLCV set to manual control. LLCV set to 70% open. Fill completed in 30 seconds. LLCV set back to 35.0% open. Chandra put back the lead for TE252A. Chandra lifted the lead for TE202B. Kyle put the CP3 LLCV into PID and disabled. The script to fill CP3 was run: vacuum@vacuum1:/ligo/home/patrick.thomas/svn/scripts$ python cp3_fill.py 50 -30 3600 Starting CP3 fill. TC B error. LLCV enabled. LLCV set to manual control. LLCV set to 50% open. Fill completed in 110 seconds. LLCV set back to 19.0% open. Chandra put back the lead for TE202B. Both scripts are in svn under /trunk/scripts in the projects repository. Revision 4023.